PRODUCT SKU : 1746SC-INO4I

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1746SC-INO4I is a high-precision analog output module for the SLC 500 system, offering four isolated output channels with fast response and versatile signal compatibility. It supports multiple current and voltage ranges and provides reliable electrical isolation for safe operation in industrial environments.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: SLC 500

  • Model / Part Number: 1746SC-INO4I

  • Product Type: Analog Output Module

  • Weight: 1.13 lbs (0.51 kg)

  • Channels: 4 isolated output channels

  • Output Current Range: 0–20 mA, 0–21 mA, 4–20 mA

  • Input Voltage Range: 0–5 V

  • Resolution: 16 bits

  • Step Response: 1 ms to 95% of full scale

  • Full Scale Output: 21 mA

  • Electrical Isolation: Field wiring to backplane: 500 VAC continuous; Channel-to-channel: 500 VAC continuous

  • Output Impedance: >1 MΩ

  • Maximum Load Resistance: 500 MΩ

  • Operating Temperature: 0–60°C

  • Backplane Current: 120 mA @ 5 VDC, 250 mA @ 24 VDC

  • Power Dissipation: 5 W maximum

  • Enclosure Type: Open

Key Features

  • Four fully isolated analog output channels for precise signal control

  • Supports multiple current and voltage ranges for flexible integration

  • Fast 1 ms step response suitable for dynamic control applications

  • High-resolution 16-bit output for accurate analog signal generation

  • Robust electrical isolation ensures safe operation across modules

Application Scenarios

  • Controlling actuators, valves, and analog devices in SLC 500 systems

  • Integrating with industrial process control and monitoring setups

  • Upgrading or replacing legacy SLC 500 analog output modules

FAQs

Q: What analog signals does this module support?
A: Supports 0–20 mA, 0–21 mA, 4–20 mA and 0–5 V input.

Q: How many isolated outputs does it have?
A: Four isolated analog outputs for safe multi-channel operation.

Q: What is the maximum operating temperature?
A: 60°C for standard industrial conditions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more