Skip to content

What are you looking for?


You may also like

1734-ACNR | Allen Bradley | POINT I/O ControlNet Adapter Module1734-ACNR | Allen Bradley | POINT I/O ControlNet Adapter Module1734-ACNR | Allen Bradley | POINT I/O ControlNet Adapter Module
1734-ACNR | Allen Bradley | POINT I/O ControlNet Adapter Module
1734-ACNR | Allen Bradley | POINT I/O ControlNet Adapter Module
1734-ACNR | Allen Bradley | POINT I/O ControlNet Adapter Module

1734-ACNR | Allen Bradley | POINT I/O ControlNet Adapter Module


Only 10 left - Selling fast

PRODUCT SKU : 1734-ACNR

PRODUCT TYPE : Programmable Controllers

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1734-ACNR functions as a high-performance communication interface for the POINT I/O™ platform. This adapter enables seamless data exchange between a ControlNet network and up to 63 POINT I/O modules. We supply this unit as 100% Brand New and Original, featuring dual BNC connectors to support redundant media topologies. It bridges the gap between your central controller and distributed field devices, ensuring deterministic I/O performance in complex automation architectures.

Technical Specifications

The 1734-ACNR manages power distribution and network traffic within the following parameters:

Feature Specification
Module Type ControlNet Adapter (Redundant)
Input Voltage 24V DC Nominal (10–28.8V DC)
POINTBus Current 1000 mA
Power Consumption 8.0 Watts
Power Dissipation 2.8 Watts @ 28.8V DC
Inrush Current 6 Amps for 10 ms
Power Requirements 425 mA
Overvoltage Protection Reverse Polarity Protected
Network Interface Dual (2) ControlNet BNC Ports
Weight 4.44 lbs (2.01 kg)

Engineering Advantages

  • Redundant Media Support: The 1734-ACNR features dual BNC ports. If the primary ControlNet cable sustains damage or signal loss, the adapter instantly switches to the redundant path. This prevents system downtime and maintains continuous process control.

  • High-Density Power Management: An integrated power supply provides 1000 mA of POINTBus current. This capacity allows the adapter to power a significant number of I/O modules directly from the backplane, reducing the need for additional 1734-EP24DC expansion power supplies.

  • Rugged Electrical Protection: Built-in reverse polarity protection prevents hardware failure during installation errors. The module also handles high inrush currents (up to 6A), ensuring stability during system power-up cycles in large-scale industrial racks.

  • Deterministic Networking: ControlNet protocol ensures that time-critical I/O data arrives exactly when the processor expects it. This eliminates network jitter, which is essential for high-speed packaging or assembly lines.

  • Tool-Free Installation: The module snaps directly onto a standard DIN rail. Its compact vertical orientation saves significant cabinet space, making it ideal for distributed junction boxes where interior room is limited.

FAQs

  • What is the maximum number of I/O modules this adapter can support?

    The 1734-ACNR supports up to 63 POINT I/O modules. However, you must calculate the total current draw to ensure it does not exceed the 1000 mA POINTBus limit.

  • Does this unit arrive in original factory packaging?

    Yes. We guarantee this 1734-ACNR is 100% Brand New and Original. It ships in the manufacturer's sealed box with the unique GTIN (10612598283702) and quality control stamps intact.

  • Can I use this adapter in a non-redundant ControlNet setup?

    Yes. While the "R" in ACNR stands for Redundant, the module functions perfectly in a single-cable configuration. Simply connect your network to Port A and leave Port B available for future expansion or redundancy.

  • What type of power supply should I use for the input voltage?

    Use a regulated 24V DC power supply. Ensure the supply can handle the 6A inrush current to prevent voltage drops during the initial power-on sequence.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more