Skip to content

What are you looking for?


You may also like

1492-IFM40DS120A-4 | Allen-Bradley | 1492 Series Digital Interface Module1492-IFM40DS120A-4 | Allen-Bradley | 1492 Series Digital Interface Module1492-IFM40DS120A-4 | Allen-Bradley | 1492 Series Digital Interface Module
1492-IFM40DS120A-4 | Allen-Bradley | 1492 Series Digital Interface Module
1492-IFM40DS120A-4 | Allen-Bradley | 1492 Series Digital Interface Module
1492-IFM40DS120A-4 | Allen-Bradley | 1492 Series Digital Interface Module

1492-IFM40DS120A-4 | Allen-Bradley | 1492 Series Digital Interface Module


Only 10 left - Selling fast

PRODUCT SKU : 1492-IFM40DS120A-4

PRODUCT TYPE : Digital Interface Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1492-IFM40DS120A-4 functions as a high-density digital interface module designed to bridge PLC I/O modules with field-side devices. This 40-pin module optimizes cabinet space by consolidating complex wiring into a streamlined, fixed terminal block architecture. It specifically handles 120V AC digital signals and incorporates advanced diagnostic features, such as blown fuse indicators, to minimize system downtime. We supply this unit as 100% Brand New and factory-original, ensuring maximum electrical conductivity and long-term terminal integrity for your automation control panels.

Technical Specifications

The 1492-IFM40DS120A-4 utilizes a specialized layout to manage isolated extra terminals and high-voltage AC signals.

Feature Specification
Module Type Digital Interface Module (IFM)
Pin Count 40 Pins
Operating Voltage 120V AC
Terminal Type Fixed Terminal Block
Diagnostics LED Status Indication
Protection Blown Fuse Indicators for Inputs
Wiring Layout Four Isolated Terminals per I/O Connection
Product Series 1492 Wiring Systems
Weight 0.60 lbs (0.27 kg)

Engineering Advantages

  • Rapid Diagnostic Feedback: Integrated LED indicators provide real-time visual status for each I/O point. This feature allows technicians to identify failed circuits at a glance without probing individual terminals with a multimeter, significantly accelerating site maintenance.

  • Enhanced Input Protection: The module features an isolated extra terminal with a dedicated blown fuse indicator for input channels. This safeguard isolates electrical faults at the interface level, preventing surges from reaching and damaging expensive PLC I/O cards.

  • High-Density Wiring Efficiency: The 40-pin design allows for a massive reduction in point-to-point manual wiring. By using pre-wired cables to connect the PLC to this IFM, you eliminate the risk of cross-wiring and reduce labor costs during panel assembly.

  • Clean Signal Isolation: The "four per I/O" terminal configuration provides dedicated paths for signal, return, and extra isolated connections. This architecture reduces electromagnetic interference (EMI) and crosstalk between adjacent 120V AC circuits, ensuring logic stability in electrically noisy environments.

FAQs

  • Does the 1492-IFM40DS120A-4 support DC voltage?

    No. Allen-Bradley specifically engineered this module for 120V AC digital circuits. Applying DC voltage or different AC levels may prevent the LED indicators from functioning correctly or cause premature component failure.

  • How do I identify a blown fuse on this module?

    The module includes dedicated blown fuse indicators. When a fuse fails, the corresponding diagnostic LED illuminates or changes state (depending on your configuration), allowing you to pinpoint the exact input channel requiring service.

  • Is the terminal block removable?

    The 1492-IFM40DS120A-4 features a fixed terminal block design. This ensures the highest level of mechanical vibration resistance, as there are no removable plug-in connectors that could loosen over time in high-impact industrial environments.

  • Is this unit a "New-Old-Stock" or a current production item?

    Regardless of its current production cycle status at the OEM, we guarantee this unit is 100% Brand New. It arrives in its original factory packaging with pristine terminal screws and zero evidence of previous rail mounting.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more