Skip to content

What are you looking for?


You may also like

1492-EBJ3 | Allen-Bradley | 1492 Series Terminal Block End Barrier1492-EBJ3 | Allen-Bradley | 1492 Series Terminal Block End Barrier1492-EBJ3 | Allen-Bradley | 1492 Series Terminal Block End Barrier
1492-EBJ3 | Allen-Bradley | 1492 Series Terminal Block End Barrier
1492-EBJ3 | Allen-Bradley | 1492 Series Terminal Block End Barrier
1492-EBJ3 | Allen-Bradley | 1492 Series Terminal Block End Barrier

1492-EBJ3 | Allen-Bradley | 1492 Series Terminal Block End Barrier


Only 10 left - Selling fast

PRODUCT SKU : 1492-EBJ3

PRODUCT TYPE : Terminal Block End Barrier

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1492-EBJ3 functions as the essential finishing component for the Allen-Bradley 1492 screw-type terminal block assembly. This end barrier provides the necessary insulation and physical closure for the open side of a terminal block stack. It prevents accidental contact with live internal bus bars and ensures the entire DIN rail assembly meets industrial safety standards. We supply this unit as 100% Brand New original hardware, guaranteeing a precise mechanical fit and consistent dielectric protection for your control panel wiring.

Technical Specifications

The 1492-EBJ3 features a low-profile design optimized for high-density DIN rail configurations:

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Part Number 1492-EBJ3
Product Type Terminal Block End Barrier
Compatible Style Screw-Type Terminal Blocks (J3 Series)
Mounting Type Snap-on Mounting
Dimensions 1.5 x 33.35 x 60 mm
Color Gray
Weight 0.04 lbs (approx. 18g)
Material High-Grade Industrial Polyamide

Engineering Advantages

  • Enhanced Finger Safety: The 1492-EBJ3 seals the exposed conductive parts of the last terminal block in a row. This creates an IP20-rated touch-safe environment, protecting maintenance personnel from electrical shock during routine inspections.

  • Instant Snap-On Integration: The tool-less mounting design allows for rapid installation. Technicians simply snap the barrier onto the end of the terminal stack, where it locks securely into place without additional fasteners.

  • Effective Creepage & Clearance: By physically separating adjacent circuits and closing off the stack, this barrier maintains required creepage and clearance distances. This prevents electrical arcing between high-voltage blocks and grounded enclosure surfaces.

  • Durable Industrial Construction: The high-grade gray polyamide material resists mechanical impacts and withstands the thermal fluctuations common in industrial control cabinets.

  • Standardized Form Factor: The 1.5mm thickness minimizes the horizontal footprint on the DIN rail. This allows engineers to maximize terminal density while still adhering to strict electrical isolation protocols.

Installation Guidelines

  1. Placement: Identify the open side of the final 1492-J3 (or compatible) terminal block in your DIN rail assembly.

  2. Alignment: Align the 1492-EBJ3 profile with the shape of the terminal block. Ensure the locking tabs line up with the corresponding recesses on the block.

  3. Engagement: Press the barrier firmly against the block until the snap-on mechanism engages. The barrier must sit flush against the terminal block to provide a complete seal.

  4. Final Check: Verify that no conductive bus bars or metal parts remain visible from the side of the assembly.

FAQs

Q: Why do I need the 1492-EBJ3 for my terminal block stack?

A: IEC-style terminal blocks typically feature one open side to facilitate internal bridging. The 1492-EBJ3 closes this open side, preventing short circuits and providing necessary electrical insulation for the end of the row.

Q: Is the 1492-EBJ3 compatible with spring-clamp (finger-safe) blocks?

A: The 1492-EBJ3 specifically matches the profile of screw-type terminal blocks, such as the 1492-J3 series. Spring-clamp modules usually require a different barrier profile tailored to their specific housing dimensions.

Q: Can I use this barrier to separate different voltage levels on the same rail?

A: Yes. Beyond serving as an end cap, engineers often insert the 1492-EBJ3 between groups of terminal blocks to provide a physical and visual divider between different circuit types or voltage levels.

Q: Does this end barrier require a DIN rail end anchor?

A: While the 1492-EBJ3 snaps onto the block itself, you should always use an end anchor (like the 1492-EAJ35) to keep the entire terminal block assembly and the end barrier from sliding along the DIN rail.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more