PRODUCT SKU : 1734-0E2V

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1734-OE2V is a POINT I/O analog output module designed to provide two single-ended, non-isolated voltage outputs. Compact and lightweight, it integrates seamlessly into POINT I/O systems, offering fast conversion rates and high-resolution signal processing. With a signed integer data format and 14-bit resolution, the module ensures precise voltage control for industrial automation applications.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line POINT I/O 1734 Series

  • Product Type Analog Output Module

  • Part Number 1734-OE2V

  • Weight 0.13 lbs (0.06 kg)

  • Outputs 2 single-ended, non-isolated analog voltage outputs

  • Output Voltage Range 0–10 V DC

  • Current Load 3 mA

  • Conversion Type Digital-to-Analog

  • Conversion Rate 20 µs

  • Data Format Signed integer

  • Resolution 14-bit

  • Operating Temperature –20 to 55 °C

Application Scenarios

  • Machine-level automation requiring precise voltage signal control

  • Distributed POINT I/O systems with compact analog output needs

  • Industrial environments needing fast conversion and high-resolution outputs

FAQ

Q: How many outputs does the 1734-OE2V provide?  A: It supports two single-ended, non-isolated voltage outputs.

Q: What is the resolution of the module?  A: The module offers 14-bit resolution for accurate signal processing.

Q: What is the conversion rate?  A: 20 microseconds per conversion.

Comparable Models

  • 1734-OE2V: 2-channel voltage output module (this model)

  • 1734-IE2V: 2-channel voltage input module

  • 1734-OE4V: 4-channel voltage output module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more