Skip to content

What are you looking for?


You may also like

1734sc-IE4CH | Allen-Bradley | POINT I/O 4-Channel Analog HART Input Module1734sc-IE4CH | Allen-Bradley | POINT I/O 4-Channel Analog HART Input Module1734sc-IE4CH | Allen-Bradley | POINT I/O 4-Channel Analog HART Input Module
1734sc-IE4CH | Allen-Bradley | POINT I/O 4-Channel Analog HART Input Module
1734sc-IE4CH | Allen-Bradley | POINT I/O 4-Channel Analog HART Input Module
1734sc-IE4CH | Allen-Bradley | POINT I/O 4-Channel Analog HART Input Module

1734sc-IE4CH | Allen-Bradley | POINT I/O 4-Channel Analog HART Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1734sc-IE4CH

PRODUCT TYPE : Analog HART Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1734sc-IE4CH serves as a specialized high-density analog input module for the Allen-Bradley POINT I/O platform. It provides four channels of 4-20mA analog input while simultaneously enabling HART (Highway Addressable Remote Transducer) protocol communication. This module allows engineers to extract secondary process variables and device diagnostics directly from smart field instruments without additional hardware. We supply this module as 100% Brand New and factory-original, ensuring full hardware integrity for your mission-critical process loops.

Technical Specifications

This module features high-resolution conversion and robust electrical isolation to maintain signal purity in industrial environments.

Feature Specification
Number of Inputs 4 Analog + HART Channels
Resolution 16-bit
Signal Range 4–20 mA
HART Variables PV, SV, TV, FV (Primary, Secondary, Tertiary, Quaternary)
Accuracy < 0.1% of range (0 °C to 25 °C)
Input Impedance 250 Ohms (Typical)
Sampling Time 33 ms (@480 Hz) to 488 ms (@50/60 Hz)
Overcurrent Protection 28 mA Continuous
Isolation 50 VDC Field-to-Backplane / 10 VDC Channel-to-Channel

Engineering Advantages

  • HART Data Integration: The 1734sc-IE4CH captures advanced diagnostic data and multi-variable information from smart transmitters. This capability enables predictive maintenance by monitoring device health and secondary process parameters (TV/FV) over the existing 4-20mA wiring.

  • High-Precision Signal Processing: The 16-bit resolution ensures granular data acquisition for sensitive applications. It detects minute fluctuations in process variables, allowing the controller to execute more precise adjustments in closed-loop systems.

  • Enhanced Channel Isolation: The 10 VDC channel-to-channel isolation minimizes ground loop interference and prevents signal "crosstalk" between adjacent inputs. This ensures that a fault on one instrument does not corrupt the data from the remaining three channels.

  • Compact Single-Slot Design: The module fits into a standard POINT I/O base. It provides four HART-enabled channels in a single slot width, maximizing I/O density in small junction boxes and reducing overall cabinet hardware costs.

FAQs

  • Does the 1734sc-IE4CH require a specific terminal base?

    The module installs into any standard 1734-TB or 1734-TBS terminal base. Ensure the base remains correctly keyed to the analog input module to prevent incorrect module insertion.

  • Can I use this module for standard 4-20mA signals without HART?

    Yes. The module functions as a high-precision 16-bit analog input module for standard 4-20mA transmitters. You can enable or disable the HART communication features via the software configuration.

  • How does the 1734sc-IE4CH handle field-side power?

    The module draws backplane power for its internal logic, but you must provide field-side power to your 4-20mA transmitters. Verify that your power supply maintains the required voltage for the 250 Ohm typical impedance of each channel.

  • What software environment supports the HART variables?

    You configure the 1734sc-IE4CH using Studio 5000 Logix Designer. The HART variables (PV, SV, TV, FV) map directly into the controller's tag database for easy access in your control logic or HMI.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more