Skip to content

What are you looking for?


You may also like

ProSoft | 5201-DFNT-DH485 | Allen Bradley | EtherNet/IP to DH-485 GatewayProSoft | 5201-DFNT-DH485 | Allen Bradley | EtherNet/IP to DH-485 GatewayProSoft | 5201-DFNT-DH485 | Allen Bradley | EtherNet/IP to DH-485 Gateway
ProSoft | 5201-DFNT-DH485 | Allen Bradley | EtherNet/IP to DH-485 Gateway
ProSoft | 5201-DFNT-DH485 | Allen Bradley | EtherNet/IP to DH-485 Gateway
ProSoft | 5201-DFNT-DH485 | Allen Bradley | EtherNet/IP to DH-485 Gateway

ProSoft | 5201-DFNT-DH485 | Allen Bradley | EtherNet/IP to DH-485 Gateway


Only 10 left - Selling fast

PRODUCT SKU : 5201-DFNT-EGD

PRODUCT TYPE : Gateway Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 5201-DFNT-DH485 gateway module from ProSoft Technology provides a communication bridge between EtherNet/IP and DH-485 networks. Designed for Rockwell Automation environments, it enables seamless data exchange between modern Ethernet-based controllers and legacy DH-485 devices.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Model: 5201-DFNT-DH485

  • Part Number: 5201-DFNT-DH485

  • Product Type: Gateway Module

  • Power Supply: 24 VDC nominal (18–32 VDC range)

  • Current Load: 500 mA max @ 32 VDC

  • Operating Temperature: –20°C to 50°C (–4°F to 122°F)

  • Storage Temperature: –40°C to 85°C (–40°F to 185°F)

  • Relative Humidity: 5–95% non-condensing

  • Dimensions (Standard): 5.20 × 2.07 × 4.52 in (13.2 × 5.25 × 11.48 cm)

  • Dimensions (Extended): 5.20 × 2.73 × 4.52 in (13.2 × 6.93 × 11.48 cm)

  • LED Indicators: Power, module status, application status, serial port activity, error status

  • Configuration Port: DB-9M RS-232 (no hardware handshaking)

Core Features

  • Provides EtherNet/IP to DH-485 protocol conversion

  • Compact design with standard and extended width options

  • Diagnostic LED indicators for real-time monitoring

  • RS-232 configuration port for setup and troubleshooting

  • Reliable operation across industrial temperature ranges

Application Scenarios

  • Integration of legacy DH-485 devices into EtherNet/IP networks

  • SCADA and distributed control systems requiring protocol bridging

  • Industrial automation environments needing Ethernet-to-serial connectivity

FAQ

  • Q: What protocols does the 5201-DFNT-DH485 support?  A: It supports EtherNet/IP and DH-485 communication.

  • Q: What is the operating temperature range?  A: –20°C to 50°C (–4°F to 122°F).

  • Q: How is configuration performed?  A: Through the DB-9M RS-232 port, without hardware handshaking.

Comparison with Similar Modules

  • PLX32-EIP-MBTCP: EtherNet/IP to Modbus TCP/IP gateway.

  • MVI69-MNET: Modbus TCP/IP communication module for CompactLogix systems.

  • MVI56E-MNETCR: Enhanced multi-client Modbus TCP/IP module for ControlLogix systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more