Product Overview

The Allen-Bradley 1771-RTP4 is a Remote Termination Panel designed to interface with up to 8 I/O modules, supporting both current and voltage input signals. It includes a dedicated wiring arm and requires a specified fuse for safe operation. The compact stand-alone design allows for flexible deployment in control systems while maintaining proper electrical isolation and signal integrity.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model Number: 1771-RTP4

  • Product Type: Remote Termination Panel

  • Series: 1771 I/O Modules

  • Number of I/O Modules Supported: 8

  • Electrical Features:

    • Supports current inputs

    • Supports voltage inputs with resistor

    • Cold-junction compensation: Not included

    • Frequency: 47–63 Hz

    • Fuse: 3 A, 250 V, normal blow

  • Cabling and Wiring:

    • Remote cabling: 1771-PSCC, 5.5 ft

    • Wiring arm: 1771-WF

  • Physical Dimensions: 115 × 317 × 160 mm (4.5 × 12.4 × 6.3 in)

  • Weight: 0.2 kg (0.5 lb)

  • Mounting/Location: Stand-alone or panel mount compatible

Application Scenarios

The 1771-RTP4 panel is ideal for:

  • Centralizing I/O wiring for multiple 1771 modules

  • Providing a clean interface for current and voltage signal connections

  • Stand-alone or rack-mounted I/O deployments

  • Systems requiring safe and organized I/O terminations

FAQ

Q: How many I/O modules can the 1771-RTP4 support?
A: It supports up to 8 I/O modules.

Q: Can it handle both current and voltage input signals?
A: Yes, it supports current inputs directly and voltage inputs with a resistor.

Q: What is the recommended fuse for this panel?
A: A 3 A, 250 V normal-blow fuse is required for proper operation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more
Optimizing Power Supply Sizing for Industrial Automation Systems

Optimizing Power Supply Sizing for Industrial Automation Systems

The power supply is the silent heartbeat of any industrial automation system. While engineers often prioritize processors and communication protocols, a stable power architecture remains the most critical factor for long-term reliability. In my 15 years of experience, I have found that neglecting power supply sizing often leads to ghost errors, intermittent field device failures, and costly production downtime.

Read more