Allen Bradley 20-750-ENETR PowerFlex 750-Series Dual-Port EtherNet/IP Option Module
Allen Bradley 20-750-ENETR PowerFlex 750-Series Dual-Port EtherNet/IP Option Module
Allen Bradley 20-750-ENETR PowerFlex 750-Series Dual-Port EtherNet/IP Option Module

Allen Bradley 20-750-ENETR PowerFlex 750-Series Dual-Port EtherNet/IP Option Module


Only 10 left - Selling fast

PRODUCT SKU : 20-750-ENETR

PRODUCT TYPE : Drive Communication Modules

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 20-750-ENETR provides high-performance networking capabilities for PowerFlex 750-Series Variable Frequency Drives (VFDs). This dual-port EtherNet/IP option module facilitates seamless integration between the drive and Logix-based control systems. It enables real-time data exchange, drive configuration, and advanced diagnostics over a standard industrial Ethernet backbone. We supply this module as 100% Brand New original equipment, ensuring full firmware compatibility and high-speed synchronization for your motion control applications.

Technical Specifications

The 20-750-ENETR utilizes the DPI protocol to interface with the drive while providing high-speed Ethernet connectivity to the plant network.

Feature Specification
Manufacturer Allen Bradley (Rockwell Automation)
Module Type EtherNet/IP Option Module
Drive Compatibility PowerFlex 753 and PowerFlex 755
Number of Ports 2 (RJ45)
Ethernet Data Rates 10/100 Mbps (Full or Half-Duplex)
Drive Protocol DPI (Drive Peripheral Interface)
DPI Data Rate 500 Kbps
DPI Current Draw 250 mA at 14V DC
Operating Temp 0 to 40°C (32 to 104°F)
Network Topology Star, Linear, or Device Level Ring (DLR)

Engineering Advantages

  • DLR Topology Support: The dual-port design allows the implementation of a Device Level Ring (DLR) topology. This enhances network resiliency by providing a redundant communication path; the network continues to operate without interruption even if a single cable segment fails.

  • Simplified Drive Commissioning: This module eliminates the need for complex serial adapters. Engineers configure the drive directly through Studio 5000 Logix Designer or Connected Components Workbench software via the Ethernet port, significantly reducing startup time.

  • Advanced Internal Diagnostics: The module monitors drive status and internal parameters in real-time. It pushes critical fault data and energy consumption metrics directly to the HMI or controller, allowing for proactive maintenance and reduced unscheduled downtime.

  • High-Speed Synchronization: The 10/100 Mbps data rate ensures low-latency command execution. The module handles high-bandwidth traffic effectively, preventing network bottlenecks during large-scale data transfers or high-axis count coordination.

FAQs

  • Does the 20-750-ENETR require an external power supply?

    No. The module draws its required 250 mA operating current directly from the drive's internal DPI bus. This eliminates additional wiring and simplifies the physical installation within the drive's option slot.

  • Can I use this module to connect two different drives together?

    The dual ports function as an embedded switch. You use the ports to "daisy-chain" multiple drives in a linear or ring topology, which reduces the number of ports required on your primary industrial Ethernet switch.

  • How do I set the IP address for the module?

    You can set the IP address using the BOOTP/DHCP utility, through the drive’s Human Interface Module (HIM), or via software tools like Studio 5000. The module stores the address in non-volatile memory to ensure it persists after a power cycle.

  • Is this module compatible with PowerFlex 753 drives?

    Yes. While the PowerFlex 755 features a built-in Ethernet port, the 20-750-ENETR serves as the primary Ethernet interface for the PowerFlex 753. In PowerFlex 755 applications, engineers often add this module to provide a second, isolated network path or to enable DLR functionality.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more