Skip to content

What are you looking for?


You may also like

Allen-Bradley | 1715-TASIF16 | 16-Channel Simplex Analog Input Termination AssemblyAllen-Bradley | 1715-TASIF16 | 16-Channel Simplex Analog Input Termination AssemblyAllen-Bradley | 1715-TASIF16 | 16-Channel Simplex Analog Input Termination Assembly
Allen-Bradley | 1715-TASIF16 | 16-Channel Simplex Analog Input Termination Assembly
Allen-Bradley | 1715-TASIF16 | 16-Channel Simplex Analog Input Termination Assembly
Allen-Bradley | 1715-TASIF16 | 16-Channel Simplex Analog Input Termination Assembly

Allen-Bradley | 1715-TASIF16 | 16-Channel Simplex Analog Input Termination Assembly


Only 10 left - Selling fast

PRODUCT SKU : 1715-TASIF16

PRODUCT TYPE : SFP Fiber Transceiver

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Module Overview

The 1715-TASIF16 is a high-reliability termination assembly (TA) designed for the Allen-Bradley 1715 Redundant I/O system. This assembly provides the physical connection interface for up to 16 simplex analog input signals, allowing them to communicate with 1715-IF16 analog input modules. Engineered for "Mission Critical" applications such as oil and gas processing, power generation, and chemical manufacturing, the 1715-TASIF16 facilitates a fault-tolerant architecture. While the assembly itself is "Simplex" (meaning it supports a single set of field wiring), it is designed to seat within a redundant I/O baseplate, ensuring that signal integrity is maintained even during module maintenance or partial system failures.

Detailed Engineering Specifications

The 1715-TASIF16 serves as the ruggedized bridge between field instrumentation and the high-speed redundant backplane.

  • Module Type: Analog Input Termination Assembly (TA)

  • Configuration: Simplex (Single field wiring path)

  • Number of Channels: 16 Channels

  • Signal Type: Analog Input (typically 4–20 mA or 0–10V DC)

  • Connectivity: Dual-port interface for module redundancy

  • System Compatibility: 1715 Redundant I/O System / 1715-IF16 Modules

  • Mounting: Plugs directly into the 1715-A3IO or 1715-A6IO baseplate

  • Field Termination: Screw-terminal or spring-clamp (depending on the RTB used)

  • Isolation: Galvanic isolation between field signals and the system backplane

  • Operating Temperature: -25°C to 70°C (-13°F to 158°F)

  • Storage Temperature: -40°C to 85°C (-40°F to 185°F)

  • Physical Weight: 0.45 lbs (0.20 kg)

Fault-Tolerant Architecture

A key design feature of the 1715-TASIF16 is its "Dual Port" capability. In a redundant configuration, two 1715-IF16 modules are plugged into the baseplate side-by-side. The termination assembly maps the 16 field signals to both modules simultaneously. If one module fails or is removed for calibration, the second module continues to process the analog data without interruption. This "Hot-Swap" capability ensures that the control loop remains closed and the process stays online, significantly reducing the risk of unplanned downtime.

Installation and Field Wiring

The 1715-TASIF16 is a passive component that contains no active electronics, which contributes to its high MTBF (Mean Time Between Failures). It is installed onto the 1715 baseplate by aligning the heavy-duty connectors and securing it with the integrated mounting screws. Field wiring for the 16 analog channels is then landed on the associated terminal block. To ensure the highest level of noise immunity, shielded twisted-pair cabling is recommended, with the shields properly landed on the assembly’s grounding bar.

Technical FAQ

What is the difference between a Simplex and a Duplex termination assembly?

The 1715-TASIF16 (Simplex) provides one set of terminals for 16 field devices. A Duplex TA would provide redundant terminal paths for each field device, typically used in SIL-3 safety applications where even a loose wire on a terminal block must be mitigated.

Does this assembly support HART communication?

Yes. When used with the 1715-IF16 module, the 1715-TASIF16 supports the pass-through of HART digital signals, allowing for remote asset management and device diagnostics via the EtherNet/IP network.

Is an external power supply required for the assembly?

The assembly itself is passive. However, the analog loops connected to it (such as 2-wire transmitters) will require a 24V DC loop power source, which can often be distributed through the 1715 system's power architecture.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more