Product Overview

The Allen Bradley 1791-OB16 functions as a self-contained, high-density digital output interface for distributed control systems. This 24V DC Block I/O module manages sixteen independent outputs, allowing for efficient control of solenoids, actuators, and motor starters without the need for a traditional I/O chassis. We supply this unit as 100% Brand New original stock, ensuring factory-spec performance for legacy Remote I/O (RIO) network extensions.

Technical Specifications

The 1791-OB16 provides high-speed switching capabilities within a ruggedized standalone footprint.

Feature Specification
Manufacturer Allen Bradley (Rockwell Automation)
Output Type 24V DC Digital Output (Source)
Number of Outputs 16 Outputs
Output Voltage Range 10–30V DC
External DC Power 19.2–30V DC
Nominal Voltage 24V DC
Max. Output Current 500 mA (Vertical) / 250 mA (Horizontal)
Isolation Voltage 500V AC (Tested)
Communication Universal Remote I/O (RIO)
Operating Temperature 0°C to 60°C (32°F to 140°F)
Weight 1.19 lbs (0.54 kg)

Engineering Advantages

  • Space-Saving Standalone Design: The 1791-OB16 integrates the network adapter and the I/O interface into a single compact block. This eliminates the overhead of a separate power supply and chassis, drastically reducing the required enclosure depth and DIN rail length in remote terminal boxes.

  • Thermal Management Flexibility: The module supports both vertical and horizontal mounting. By adjusting the installation orientation, engineers can optimize airflow within the cabinet. Vertical mounting allows for higher current density (500 mA per output), maximizing the module's load-handling capability.

  • Superior Signal Isolation: Integrated 500V AC isolation protects the internal RIO communication logic from field-side voltage spikes and ground loops. This hardware barrier ensures that electrical noise on the 24V DC load circuit does not corrupt the data transmission back to the PLC-5 or SLC 500 controller.

  • Low-Leakage Precision: A maximum off-state leakage current of just 0.5 mA prevents "ghost" activation of sensitive field devices. This ensures that low-current indicators and high-impedance relays de-energize reliably when the PLC sends the "OFF" command.

FAQs

  • Can I use the 1791-OB16 with an SLC 500 or PLC-5 processor?

    Yes. The 1791-OB16 communicates via the Universal Remote I/O (RIO) protocol. Any controller equipped with an RIO scanner port (such as a PLC-5 or an SLC 5/02 with a 1747-SN module) can address this block as a standard remote I/O rack.

  • Does the mounting orientation affect the output current rating?

    Yes. Heat dissipation efficiency changes based on orientation. Vertical mounting supports up to 500 mA per output, while horizontal mounting limits the current to 250 mA per output to prevent internal overheating. Always design your thermal budget based on the intended mounting position.

  • What is the purpose of the External DC Power requirement?

    The 19.2–30V DC external power input drives the output circuitry and provides the necessary voltage for the field devices. The communication link (RIO) requires this power to be stable to ensure the module remains visible on the network and maintains its output states.

  • How do I set the address for this module on the RIO network?

    You configure the RIO station address and baud rate via internal DIP switches. As a 100% Brand New original unit, it arrives with factory default settings; you must set these switches to match your network configuration before applying power to the system.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more