Skip to content

What are you looking for?


You may also like

Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input ModuleAllen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input ModuleAllen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module
Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module
Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module
Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module

Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1794-IE8H

PRODUCT TYPE : HART Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley Flex I/O 1794 Series 1794-IE8H is an 8-point analog input module designed for HART-enabled applications. It delivers high-resolution signal conversion, configurable data formats, and robust diagnostic indicators. With DIN rail mounting and compatibility with Flex I/O terminal bases, this module provides reliable integration into distributed control systems.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: Flex I/O 1794

  • Catalog Number / Model: 1794-IE8H

  • UPC: 612598323883

  • Product Type: Flex I/O HART Analog Module

  • Weight: 0.31 lbs (0.14 kg)

  • Resolution: 16-bit

  • Conversion Method: Successive approximation

  • Inputs: 8 single-ended, non-isolated channels

  • Absolute Accuracy: ±0.1% full scale at 20 °C (68 °F)

  • Temperature Drift: ±0.05% full scale from 0–55 °C (32–131 °F)

  • Step Response (to 99%): 80 ms

  • Terminal Base Compatibility: 1794-TB3G, 1794-TB3GS

  • Indicators:

    • 8 red fault LEDs

    • 8 yellow channel LEDs

    • 1 green power LED

  • External DC Supply: Nominal 24 VDC

  • Supply Range: 19.0–31.2 VDC (with 5% AC ripple)

  • FlexBus Current Draw: 80 mA @ 5 VDC

  • Functional Data Range: >17 V @ 22 mA

  • Isolation Voltage: 50 V continuous

  • Power Dissipation: 3.9 W max @ 31.2 VDC

  • Thermal Dissipation: 13.5 BTU/hr max @ 31.2 VDC

  • Mounting: DIN rail

  • Enclosure Type: Open-style

Application Scenarios

  • Distributed control systems requiring HART-enabled analog input

  • Process industries with multiple sensor integration

  • Environments needing diagnostic indicators for fault detection

FAQ

Q: How many analog inputs does the 1794-IE8H support?  A: Eight single-ended, non-isolated inputs.

Q: What terminal bases are compatible with this module?  A: 1794-TB3G and 1794-TB3GS.

Q: Does the module provide diagnostic indicators?  A: Yes, it includes fault, channel, and power LEDs.

Comparison with Similar Models

  • 1794-IE8H: 8-channel HART analog input, 16-bit resolution.

  • 1794-IE4XOE2: Combination analog input/output module.

  • 1794-IF8: 8-channel analog input without HART functionality.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more