Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input ModuleAllen-Bradley 1756-IF8I ControlLogix Isolated Analog Input ModuleAllen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module
Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module
Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module
Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module

Allen-Bradley 1756-IF8I ControlLogix Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IF8I

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IF8I is an isolated analog input module designed for high-accuracy signal measurement in ControlLogix systems. With eight individually isolated input channels, it supports both voltage and current inputs, providing exceptional precision and noise immunity for process and automation applications.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: ControlLogix

  • Part Number: 1756-IF8I

  • Module Type: Isolated Analog Input Module

  • Number of Channels: 8 isolated analog inputs

  • Input Signal Ranges:

    • ±10V

    • 0–10V

    • 0–5V

    • 0–21 mA (current)

  • Resolution: 24-bit (1.49 µV/count for voltage, 2.99 nA/count for current)

  • Input Current Range: 0–20 mA

  • Channel Isolation: 250V continuous (reinforced or basic insulation)

  • Power Consumption:

    • 15.7 BTU/hr (voltage mode)

    • 17.4 BTU/hr (non-sourcing current mode)

    • 24.9 BTU/hr (sourcing current mode)

  • Update Time: 1 ms for floating-point values

  • Calibration: Factory calibrated, no field calibration required

Key Features

  • Multi-Mode Input Support: Handles voltage, current, and 2-wire transmitter input configurations.

  • High Accuracy and Resolution: 24-bit resolution provides precise signal measurement for demanding applications.

  • Individual Channel Isolation: Each input channel is electrically isolated to reduce noise and ensure safety.

  • Real-Time Data Sampling: Synchronized input sampling supports accurate, real-time control across the system.

  • No Field Calibration: Simplifies installation and maintenance by eliminating manual adjustments.

  • Status Indicators: Per-channel LEDs provide diagnostic and fault information for simplified troubleshooting.

Application Scenarios

  • Process Automation: Measurement of temperature, pressure, and flow signals.

  • Industrial Monitoring: Data acquisition from analog sensors and transmitters.

  • Machine Control Systems: Integration into ControlLogix racks for precision signal monitoring.

  • Energy Management: Accurate analog data input for metering and efficiency control.

FAQs

  • Q: How many input channels does the 1756-IF8I provide?
    A: The module includes eight isolated analog input channels.

  • Q: What input ranges are supported?
    A: Voltage ranges ±10V, 0–10V, 0–5V, and current range 0–21 mA.

  • Q: Does it require manual calibration?
    A: No, it is factory calibrated and requires no field calibration.

  • Q: What level of isolation does it offer?
    A: Provides up to 250V continuous isolation between channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more