Product Overview

The 1756-RM2XT provides high-speed data synchronization between primary and secondary chassis in a ControlLogix redundancy system. As an "XT" (Extended Temperature) module, it features specialized components to withstand harsher environmental conditions than standard automation hardware. This module ensures bumpless switchover during a controller or chassis failure, maintaining continuous process operation in mission-critical applications. We supply this unit as 100% Brand New original hardware, ensuring your high-availability architecture operates with factory-certified precision and thermal resilience.

Technical Specifications

The 1756-RM2XT utilizes advanced fiber optic technology to maintain real-time chassis synchronization:

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Module Type Enhanced Redundancy Module (XT Series)
Fiber Optic Support Single-channel (1)
Max Cable Length 4 Kilometers
Wavelength 1300 nm
Transmission Speed 1000 Mbps (1 Gbps)
Operating Temp -25°C to +70°C (-13°F to +158°F)*
Dimensions 5.51 x 4.41 x 5.71 inches
Weight 0.29 kg (0.64 lb)
Wire Size 20 AWG (for grounding)

Note: While standard specs list 0-60°C, the XT designation officially supports expanded ranges up to 70°C when installed in appropriate XT chassis.

Engineering Advantages

  • Long-Distance Synchronization: The 1300 nm fiber optic interface supports cable runs up to 4 kilometers. This allows engineers to physically separate redundant chassis in different fire zones or remote control rooms to protect against localized disasters.

  • Bumpless Switchover Performance: The 1000 Mbps (1 Gbps) transmission speed ensures near-instantaneous data mirroring. During a fault, the 1756-RM2XT facilitates a switchover so fast that the field actuators and remote I/O perceive no interruption in the control logic.

  • Extended Thermal Durability: The XT-series construction utilizes robust internal components and superior heat dissipation designs. This solves the pain point of hardware failure in non-climate-controlled cabinets or extreme outdoor environments.

  • Fiber Optic Isolation: By using fiber optics for chassis synchronization, the module provides total electrical isolation between redundant pairs. This eliminates ground loops and protects the control system from high-voltage surges or electromagnetic interference (EMI).

  • Simplified Redundancy Setup: The module handles complex synchronization tasks automatically. Once connected via fiber, it manages the scan list and data table mirroring without requiring manual code-heavy synchronization routines from the programmer.

FAQs

Q: Can I use the 1756-RM2XT with a standard 1756-RM2 module?

A: No. For a redundant pair to function correctly, both modules must share the same hardware series and firmware revision. We recommend using two 1756-RM2XT modules to ensure consistent thermal performance and synchronization timing.

Q: What type of fiber optic cable does this module require?

A: The 1756-RM2XT requires 62.5/125 micron multi-mode fiber optic cable. Ensure you use high-quality LC-style connectors to maintain the 1000 Mbps transmission integrity over long distances.

Q: Does this module require a separate power supply?

A: No. The 1756-RM2XT draws its power directly from the ControlLogix backplane. However, you must ensure the chassis power supply (such as a 1756-PA75R) provides sufficient current for the entire redundancy set.

Q: Why should I choose the "XT" version over the standard 1756-RM2?

A: Choose the 1756-RM2XT if your installation site experiences temperatures outside the standard 0-60°C range. The XT version specifically targets applications in oil and gas, mining, and remote pumping stations where environmental control is limited.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more