Skip to content

What are you looking for?


You may also like

1756-OF8H | Allen-Bradley | ControlLogix HART Output Module1756-OF8H | Allen-Bradley | ControlLogix HART Output Module1756-OF8H | Allen-Bradley | ControlLogix HART Output Module
1756-OF8H | Allen-Bradley | ControlLogix HART Output Module
1756-OF8H | Allen-Bradley | ControlLogix HART Output Module
1756-OF8H | Allen-Bradley | ControlLogix HART Output Module

1756-OF8H | Allen-Bradley | ControlLogix HART Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-OF8H

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 1756-OF8H is a high-performance ControlLogix analog output module featuring eight individually isolated channels with integrated HART (Highway Addressable Remote Transducer) protocol capabilities. This module is specifically designed for complex process control environments where digital communication with smart field devices is required over standard 4-20mA analog signals. By utilizing the 1756-OF8H, engineers can access advanced device diagnostics and configuration data directly through the Logix controller without the need for external HART multiplexers. Each channel provides robust 250V continuous reinforced insulation, ensuring signal integrity and equipment protection in demanding industrial electrical environments.

Technical Specifications

  • Module Catalog Number: 1756-OF8H

  • Output Configuration: 8 Isolated Channels

  • Analog Ranges: 0…20 mA or 4…20 mA (Voltage mode via specific wiring/scaling)

  • HART Version: HART v5, v6, and v7 supported

  • Digital Resolution: 15-bit across 24mA (approx. 732 nA/bit)

  • Backplane Current Draw: 220 mA at 5.1V DC | 360 mA at 24V DC

  • Settling Time (HART Disabled): <23 ms to 95% of full scale

  • Settling Time (HART Enabled): <100 ms to 95% of full scale

  • Isolation Voltage: 250V AC continuous (Reinforced Insulation Type)

  • Power Dissipation: 6.5 Watts Maximum

  • Thermal Dissipation: 22.2 BTU/hr

  • Operating Temperature: 0°C to +60°C (32°F to +140°F)

  • Mechanical Integrity: 30g peak shock; 2g vibration at 10-500 Hz

Application and Comparison

The 1756-OF8H is typically deployed in chemical processing, oil and gas, and pharmaceutical manufacturing where "smart" instrumentation is standard. Unlike the standard 1756-OF8, the 1756-OF8H allows for simultaneous analog control and digital asset management. Its isolated architecture is superior for systems where grounding loops or electrical interference between channels could compromise process stability.

FAQ

Does the 1756-OF8H require a separate HART modem for configuration?No, the module acts as a HART master, allowing Asset Management Software (like FactoryTalk AssetCentre) to communicate directly with field instruments through the ControlLogix backplane.

Can I mix current and voltage outputs on this module?While primarily optimized for current-based HART loops, the module can be configured for voltage outputs; however, HART communication is only available when operating in current mode.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more