PRODUCT SKU : 1757-EN2TR

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1756-EN2TR functions as a high-performance communication interface for the ControlLogix platform. This dual-port EtherNet/IP module enables real-time data exchange between controllers, I/O devices, and HMI systems. It supports high-speed industrial networking protocols and provides the necessary bandwidth for complex, distributed automation architectures. We supply this module as 100% Brand New and Original, ensuring your critical control system operates with factory-certified networking stability.

Technical Specifications

The 1756-EN2TR manages high-volume data traffic while maintaining low thermal overhead within the ControlLogix chassis.

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Product Line: ControlLogix

  • Module Type: EtherNet/IP Communication (Dual-Port)

  • TCP Connections: 128 Maximum

  • I/O Packet Rate: 25,000 Packets per second

  • HMI/MSG Packet Rate: 2,000 Packets per second

  • Ethernet Speed: 10/100 Mbps (Auto-negotiation)

  • Backplane Current Draw: 1 Amp @ 5.1V DC; 3 mA @ 24V DC

  • Power Dissipation: 5.1 Watts

  • Thermal Dissipation: 17.4 BTU per Hour

  • Socket Services: Supported

Engineering Advantages

  • Native Device Level Ring (DLR) Support: The dual-port design allows the module to act as a node in a Device Level Ring topology. This architecture ensures network resiliency; if a single cable fault occurs, the ring automatically redirects traffic in milliseconds, preventing system downtime.

  • High-Density Connectivity: This module supports up to 128 simultaneous TCP connections. It easily manages large-scale deployments involving numerous HMI stations, remote I/O racks, and peer-to-peer controller communications without performance degradation.

  • Optimized I/O Throughput: The 1756-EN2TR handles an I/O packet rate of 25,000 packets per second. This capacity solves bottleneck issues in high-speed motion control or complex manufacturing lines where rapid data refresh rates remain critical.

  • Simplified Troubleshooting and Maintenance: Integrated web-based diagnostics and port status LEDs provide immediate feedback on network health. Maintenance teams can identify port-specific errors or cabling issues at a glance, reducing Mean Time to Repair (MTTR).

FAQs

  • Does the 1756-EN2TR require a specific slot in the ControlLogix chassis?

    No. You can install the 1756-EN2TR in any available slot in a 1756 I/O chassis. However, ensure your power supply provides sufficient 5.1V current (1 Amp) to support this module along with other installed cards.

  • What is the advantage of the "TR" version over a standard "EN2T"?

    The "TR" (Two-port/Ring) designation indicates the presence of two RJ45 ports and an integrated switch. Unlike the single-port EN2T, the EN2TR supports DLR topologies and daisy-chaining, which significantly reduces the need for external Ethernet switches in the field.

  • Can I use the 1756-EN2TR for messaging to third-party devices?

    Yes. The module supports Socket Services, allowing you to establish custom Ethernet communications with non-Rockwell devices such as barcode scanners, printers, or vision systems using standard TCP/UDP protocols.

  • Is this module a direct replacement for older 1756-ENBT modules?

    Yes. The 1756-EN2TR offers significantly higher connection capacity and packet rates than the legacy 1756-ENBT. When replacing an ENBT, you may need to update the I/O configuration in Studio 5000 to match the new hardware's capabilities.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Siemens Interface Modules (IM): The Backbone of Distributed I/O

Mastering Siemens Interface Modules (IM): The Backbone of Distributed I/O

In the realm of industrial automation, efficiency depends on how effectively a system communicates with its peripherals. The Siemens Interface Module (IM) serves as the critical link in this architecture. It enables seamless data exchange between centralized controllers and decentralized hardware. Whether you are working with the S7-300, S7-1500, or ET 200 series, understanding the IM is essential for modern control systems.

Read more
Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Dynamic Data Exchange (DDE) remains a vital legacy protocol for industrial communication. Originally for general computing, it now bridges the gap between factory floor data and enterprise reporting. This enduring method provides a foundational link for integrating real-time software layers in modern industrial automation.

Read more
Master FIFO and LIFO Sequences for Advanced PLC Logic

Master FIFO and LIFO Sequences for Advanced PLC Logic

In industrial automation, managing data flow is as critical as hardware control. This guide explores how FIFO and LIFO sequential logic can optimize your control systems. Master these essential tools to build more efficient sorting, inventory tracking, and data management workflows for any modern factory.

Read more