Product Overview

The Yokogawa KS1-20 acts as a high-integrity signal transmission bridge between I/O modules and terminal boards within the CENTUM series architecture. This 40-to-40 pin interface cable handles multi-channel analog and digital data routing with minimal signal attenuation. Engineered for long-distance cabinet-to-cabinet patching, this cable ensures seamless communication across the process control network. We supply this product as 100% Brand New, ensuring factory-certified conductivity and insulation for mission-critical applications.

Part Number Breakdown

The KS1 series follows a modular nomenclature to define connector type, length, and hardware revision:

Code Segment Specification Description
KS1 Model Signal Cable with 40-40 pin configuration
-20 Length Specifies a cable length of 20 meters
*B Style Style B hardware revision for optimized shielding

Technical Specifications

The KS1-20 provides a robust physical link designed to withstand the rigors of industrial cabinet environments.

  • Manufacturer: Yokogawa

  • Interface Type: 40-pin to 40-pin connectors

  • Cable Length: 20 Meters (Maximum standard length)

  • Style Code: Style B (Current revision)

  • Application: Connects I/O modules to terminal units or power distribution boards

  • Signal Type: Multi-core signal transmission

  • Condition: 100% Brand New and Original

Engineering Advantages

The KS1-20 addresses critical wiring challenges in large-scale plant deployments:

  • Extended Reach for Remote Racks: The 20-meter length permits flexible positioning of terminal boards relative to the CPU or I/O rack. This solves the problem of rigid cabinet layouts and allows engineers to centralize field wiring in separate enclosures.

  • High-Density Connector Design: The 40-pin interface consolidates multiple signal loops into a single assembly. This reduces cable clutter, simplifies cable management, and significantly cuts down on labor hours during system commissioning.

  • Signal Cross-talk Suppression: The Style B revision incorporates improved internal twisting and shielding techniques. These features reject electromagnetic interference (EMI) from nearby power cables, maintaining the accuracy of sensitive 4-20mA analog loops.

  • Secure Connection Locking: The industrial-grade connectors include mechanical fastening mechanisms. This prevents accidental disconnection caused by vibration or cable strain, ensuring 24/7 process uptime.

FAQs

Can I cut the KS1-20 to a shorter length in the field?

We strongly advise against field modifications. Yokogawa factory-terminates these cables with precision-molded connectors and rigorous continuity testing. Altering the cable length manually voids the warranty and risks signal integrity issues due to improper shielding termination.

How does Style B differ from the original Style A?

Style B represents a hardware improvement in materials and shielding effectiveness. While typically backward compatible with Style A applications, Style B offers superior mechanical durability and better resistance to environmental degradation in harsh industrial atmospheres.

What is the minimum bend radius for the KS1-20?

During installation, technicians must maintain a bend radius of at least six times the cable diameter. Sharp bends can damage the internal 40-core structure, leading to intermittent signal failure or permanent conductor breakage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more