Skip to content

What are you looking for?


You may also like

Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal BlockYokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal BlockYokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block
Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block
Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block
Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block

Yokogawa CENTUM VP ATR8D-00 8-Channel Redundant Pressure Clamp Terminal Block


Only 10 left - Selling fast

PRODUCT SKU : ATR8D-00

PRODUCT TYPE : Redundant Terminal Block

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The ATR8S-00 (Part No. ATR8D-00) is a specialized signal conditioning and termination interface designed for Yokogawa’s CENTUM VP and CS 3000 Field Control Stations. Engineered specifically for high-availability temperature monitoring, this unit facilitates the integration of RTD and Thermocouple sensors into the AAR181 and similar I/O modules.

The primary engineering advantage of the ATR8D-00 lies in its redundant branching capability. It allows a single set of field sensors to be cross-connected to two separate I/O modules, ensuring that a single module failure does not result in the loss of critical process data. The M3.5 pressure clamp terminals are designed to maintain a gas-tight seal, which is vital for preventing oxidation of low-millivolt signals in corrosive chemical environments.

Technical Specifications

  • Manufacturer: Yokogawa Electric Corporation

  • Model Identification: ATR8D-00

  • I/O Capacity: 8 Differential Channels

  • Redundancy Support: Dual-redundant module branching

  • Terminal Interface: M3.5 Pressure Clamp (Spring-loaded contact)

  • Dielectric Strength: 500 V AC (Terminals to Ground)

  • Insulation Resistance: 10 MΩ minimum at 500 V DC

  • Sensor Compatibility: Pt100, Pt50, JPt100 (RTD); Type K, J, T, E, B, R, S, N (TC)

  • Cold Junction Compensation: Integrated reference sensors for Thermocouple precision

  • Operating Ambient: 0°C to 60°C (32°F to 140°F)

  • Relative Humidity: 5% to 95% RH (Non-condensing)

  • Weight: 0.8 kg (1.76 lbs)

  • Origin: Made in Japan

Operational Implementation

The ATR8D-00 (ATR8D-00) is typically deployed in mid-stream and downstream oil and gas applications where temperature excursions must be monitored with zero downtime. Unlike standard screw terminals that may loosen over time due to thermal cycling, the pressure clamp mechanism provides constant force, ensuring measurement stability for sensitive RTD resistance values.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more