Skip to content

What are you looking for?


You may also like

Woodward 8273-128 2301D-ST Digital Load Sharing and Speed ControlWoodward 8273-128 2301D-ST Digital Load Sharing and Speed ControlWoodward 8273-128 2301D-ST Digital Load Sharing and Speed Control
Woodward 8273-128 2301D-ST Digital Load Sharing and Speed Control
Woodward 8273-128 2301D-ST Digital Load Sharing and Speed Control
Woodward 8273-128 2301D-ST Digital Load Sharing and Speed Control

Woodward 8273-128 2301D-ST Digital Load Sharing and Speed Control


Only 10 left - Selling fast

PRODUCT SKU : 8273-128

PRODUCT TYPE : Speed Control Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for steam turbine prime mover management, the Woodward 8273-128 (8273-128 Digital Load Sharing and Speed Control) provides direct electrical execution of speed regulation and load sharing logic within 2301D series platforms.

Hardware Specifications

Parameter Specification
Model 8273-128
Brand Woodward
Input Voltage 24 VDC
Communication RS-232 Port

Actuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles

The 8273-128 maintains turbine speed stability through an integrated PID control loop that interfaces with prime mover actuators. The module features an integral power sensor to monitor load conditions and facilitates load sharing via an analog network input. To ensure stability during rapid process shifts, the internal control architecture supports a programmed valve ramp, which regulates the actuator loop feedback response to prevent mechanical overshoot. The module housing is designed with thermal heat sink dissipation profiles to manage internal electronics temperatures during continuous duty cycle operations in industrial control enclosures. Users may utilize the RS-232 serial port for field-configurable programming of operational parameters to match the specific dynamic requirements of the steam turbine.

Frequently Asked Questions

Q: Is the 8273-128 compatible with legacy 2301A series hardware?

A: Yes, the 8273-128 is designed to be configurable for operation within environments previously supported by 2301A controllers. Verification of terminal wiring and software logic settings is required to ensure signal compatibility during replacement or retrofitting.

Q: How is the load sharing network interface isolated from the control logic?

A: The analog load sharing network input is integrated into the module signal path to allow paralleling with other governors. Signal isolation practices, such as the use of high-quality shielded cabling, must be followed to prevent ground loops that could degrade the load sharing accuracy.

Field Installation Guidelines

  • Mounting: Install the controller in a vertical orientation within the cabinet to allow for convective airflow. Ensure that the module is isolated from excessive heat sources and high-vibration engine components.
  • Wiring: Utilize the RS-232 port for initial configuration via a compatible terminal emulator. Ensure all communication cables are shielded and that the shield is grounded at the control system common point only to minimize electromagnetic noise.
  • Grounding: Connect the 24 VDC power common and chassis ground as per standard industrial instrumentation practices. A low-impedance path to the cabinet protective earth is required for surge protection and electromagnetic compatibility.
  • Interface Setup: Verify all valve ramp settings and PID gains through the field-configurable software interface prior to the first startup of the steam turbine.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more