PRODUCT SKU : UR8LV

PRODUCT TYPE : CT/VT Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview  The GE UR8LV CT/VT Module is a precision measurement unit within the Fanuc Multilin Universal Relay (UR) series. It is designed to capture accurate current and voltage data, ensuring reliable monitoring and protection in power system applications. With its robust construction and DIN rail mounting capability, the UR8LV is suitable for demanding industrial environments.

Technical Specifications

  • Manufacturer: General Electric Fanuc Multilin

  • Model: UR8LV

  • Type: CT/VT Module

  • Input Voltage Range: 120 V AC to 480 V AC

  • Input Current Range: 1 A to 5 A

  • Burden Rating: 1 VA

  • Frequency Range: 50/60 Hz

  • Operating Temperature: -40°C to +70°C (-40°F to +158°F)

  • Storage Temperature: -40°C to +85°C (-40°F to +185°F)

  • Dimensions: 180 mm × 100 mm × 40 mm

  • Weight: 1.0 kg

  • Mounting Type: DIN rail mountable

Key Features

  • High-performance CT/VT measurement for accurate system monitoring

  • Wide input voltage and current ranges for flexible application

  • Compact DIN rail mountable design for simplified installation

  • Rugged construction for reliable operation in harsh environments

Applications

  • Power generation and distribution monitoring

  • Substation automation requiring CT/VT measurement

  • Industrial process control systems

  • Relay-based protection schemes in mission-critical environments

FAQ

  • Q: What voltage range does the UR8LV support?  A: It supports input voltages from 120 V AC to 480 V AC.

  • Q: What current range can the UR8LV measure?  A: It measures currents between 1 A and 5 A.

  • Q: How is the UR8LV installed?  A: It is DIN rail mountable for easy integration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more