Skip to content

What are you looking for?


You may also like

RX3i PACSystems IC695PSA040 by GE Fanuc Power ModuleRX3i PACSystems IC695PSA040 by GE Fanuc Power ModuleRX3i PACSystems IC695PSA040 by GE Fanuc Power Module
RX3i PACSystems IC695PSA040 by GE Fanuc Power Module
RX3i PACSystems IC695PSA040 by GE Fanuc Power Module
RX3i PACSystems IC695PSA040 by GE Fanuc Power Module

RX3i PACSystems IC695PSA040 by GE Fanuc Power Module


Only 10 left - Selling fast

PRODUCT SKU : IC695PSA040

PRODUCT TYPE : Power Supply

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The IC695PSA040 is a 40-watt universal power supply module engineered for the GE Fanuc PACSystems RX3i series. Designed to provide stable, regulated power for CPUs, communication modules, and I/O devices, it supports both AC and DC input ranges for flexible deployment across diverse industrial applications. Integrated protection features ensure reliable operation under overload, short-circuit, and overheat conditions. The module occupies two RX3i rack slots and is ideal for applications requiring consistent, long-term performance.

Technical Specifications

Electrical & Power

  • Model / Part Number: IC695PSA040

  • Manufacturer: GE Fanuc Emerson

  • Product Type: RX3i Universal Power Supply

  • Power Output: 40 W total

  • Input Voltage Range:

    • AC: 85–264 VAC

    • DC: 100–300 VDC

  • Full Load Input Power: 70 W maximum

  • Output Voltages:

    • +5.1 VDC @ 8 A (logic modules)

    • +24 VDC @ 2 A (peripherals)

    • +3.3 VDC (internal use)

  • Output Current Limits:

    • +24 VDC: 0–1.6 A

    • +5.1 VDC: 0–6 A

    • +3.3 VDC: 0–9 A

  • Isolation Voltage: 250 VAC continuous, 1500 VAC 1 min (input to backplane)

  • Ripple/Noise: 150 mV max

  • Efficiency: ≥85%

  • Ride-Through Time: 20 ms

Protection & Indicators

  • Protection Features: Overload, short-circuit, overheat

  • Status LEDs: Power, Fault, Overheat, Overload

Mechanical & Installation

  • Wiring Terminals: 14–22 AWG, 6 A max per terminal

  • Mounting: Standard RX3i rack installation, occupies two slots

  • Max Power Supplies per Rack: 4

  • Operating Temperature: 0°C to 60°C

  • Storage Temperature: –40°C to 85°C

  • Humidity Range: 5–95% RH, non-condensing

  • Weight: 1.19 lbs

Applications

The IC695PSA040 is ideal for powering RX3i CPUs, communication modules, and I/O devices in factory automation, process control, and other industrial systems. Its dual AC/DC input support and integrated protections make it suitable for both standard and challenging operational environments.

FAQ / Common Questions

Q: Can this power supply operate with both AC and DC sources?
A: Yes, it supports 85–264 VAC and 100–300 VDC inputs.

Q: How many RX3i slots does the module occupy?
A: It occupies two slots per RX3i base.

Q: How many power supplies can be installed per RX3i rack?
A: Up to four units per rack.

Q: Does it provide overcurrent or overheat protection?
A: Yes, built-in protections safeguard against overload, short-circuit, and overheating.

Q: Is it suitable for industrial environments with high humidity?
A: Yes, it operates reliably in 5–95% RH, non-condensing conditions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more