Skip to content

What are you looking for?


You may also like

GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy PackGE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy PackGE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack
GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack
GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack
GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack

GE Fanuc PACSystems RX3i IC695CPK330 CPE330 CPU Kit with Energy Pack


Only 10 left - Selling fast

PRODUCT SKU : IC695CPK330

PRODUCT TYPE : Blank Slot Filler Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694ACC310 blank slot filler module is a protective accessory engineered for the GE Fanuc RX3i PACSystem. It ensures unused slots remain shielded from dust, debris, and accidental contact, while maintaining airflow and rack stability.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: RX3i PACSystem

  • Part Number: IC694ACC310

  • Product Type: Blank Slot Filler Module

  • Weight: 0.25 lbs (0.11 kg)

  • Compatibility: All RX3i CPUs

  • Supported Racks: Main rack, Expansion racks, Remote racks

  • Compatible Standard Baseplates: 7-slot, 12-slot, and 16-slot baseplates

  • Compatible Expansion Baseplates: 5-slot and 10-slot baseplates

  • Slots Covered: Single slot

  • Module Installations: Unlimited

  • Scalable Systems: Supported

  • Backplane Current Draw: None

  • Status Indicators: None

  • Programming Requirement: None

  • Communication: None

  • I/O Count: None

  • Removal/Insertion Under Power: Supported

  • Vibration Prevention: Supported

  • Water Damage Prevention: Supported

  • Product Lifecycle: Active

Application Scenarios

  • Rack Protection: Prevents dust and debris from entering unused slots.

  • Cooling Efficiency: Maintains airflow in partially filled racks.

  • System Stability: Provides mechanical support for scalable configurations.

  • Operational Flexibility: Allows safe insertion and removal under power.

FAQ

Q: Does the IC694ACC310 require programming?  A: No, it is a passive filler module with no configuration needed.

Q: Can it be installed while the system is powered?  A: Yes, safe insertion and removal under power are supported.

Q: Is it compatible with both standard and expansion baseplates?  A: Yes, it supports 7, 12, and 16-slot standard baseplates as well as 5 and 10-slot expansion baseplates.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more