Configured for rotational displacement acquisition in MMS machinery monitoring platforms, the Emerson Epro PR9670/113-100 (PR9670/113-100) Eddy Current Sensor provides direct physical execution of non-contact shaft position and vibration sensing.

Hardware Specifications

Parameter Specification
Model PR9670/113-100
Brand Emerson Epro
Origin USA
Weight Standard sensor weight
Dimensions 31 cm x 26 cm x 8 cm
Operating Temp Standard industrial range
Measurement Principle Eddy current proximity
Compatibility MMS 3000/6000 systems

Mechanical Monitoring and TSI Characteristics

The PR9670/113-100 utilizes a ferromagnetic core to generate a concentrated electromagnetic field, allowing for high-resolution displacement tracking of rotating shafts. During installation, perform precise eddy-current probe scaling to align the sensor output with the specific shaft material and geometry. Maintain gap voltage validation against -10 VDC targets to ensure operation within the linear range of the probe's characteristic curve. The internal high-frequency excitation architecture provides effective cross-talk suppression, enabling high-density mounting configurations—such as those required in multi-point monitoring arrays—without signal distortion or inter-probe interference.

Frequently Asked Questions

Q: How does the shielded cable affect signal integrity in high-noise environments?

A: The integral shielded cable is designed to provide high noise immunity by minimizing electromagnetic interference coupling into the velocity or displacement signal path. Ensure the shield is properly terminated at the monitoring system's common ground to maintain this protection.

Q: Is the stainless steel housing suitable for chemically aggressive environments?

A: The stainless steel construction provides mechanical and chemical resistance against typical industrial environmental factors such as humidity and dust. However, ensure the cable entry point is correctly sealed if the sensor is to be deployed in environments with moisture or conductive particulate ingress.

Field Installation Guidelines

  1. Secure the sensor rigidly using the housing threads, ensuring the probe tip is perpendicular to the shaft target to prevent geometric measurement errors.
  2. Verify the initial air gap using a micrometer or feeler gauge, adjusting until the static gap voltage reaches the nominal -10 VDC target.
  3. Route the shielded cable through grounded metallic conduit, avoiding proximity to high-current AC motor drives or power cables to prevent induced noise.
  4. If mounting multiple sensors in a tight array, verify that excitation frequencies are decoupled to eliminate cross-talk.
  5. Perform a static gap simulation test during commissioning to verify the mapping of the measured vibration parameters to the output current/voltage values of the monitoring system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more