Product Details

The Foxboro P0926JMA, also cataloged as the P0926JMA Modular Baseplate, operates as a dedicated hardware component for structural mounting and backplane signal bus interconnection within Foxboro I/A Series DCS environments. It provides direct physical execution of modular 8-slot Field Bus Module (FBM) carrier housing and redundant power rail distribution. The assembly routes internal communication buses while regulating backplane voltage profiles to mounted I/O modules.

Hardware Specifications

Parameter Specification
Model P0926JMA
Brand Foxboro
Origin USA
Weight 0.2 kg (0.44 lbs)
Dimensions 102.2 cm x 12.4 cm x 12.6 cm
Operating Temp 0 to +60 deg C
Power Consumption Passive (Backplane distribution: +5 VDC)
Slot Capacity 8 Slots (Modular FBM)
Mounting Type DIN Rail Mount
Storage Temp -40 to +85 deg C
Humidity Rating 5-95% RH (non-condensing)

DCS Backplane Communication and Channel Isolation

The Foxboro P0926JMA baseplate integrates high-density multi-layer printed circuit traces engineered to maintain deterministic bus communications across all 8 module positions. Designed for Foxboro I/A Series architectures, the backplane traces deliver channel-to-channel isolation between power distribution buses and differential fieldbus communication loops. It conditions +5 VDC backplane power to preserve signal integrity and support transparent pass-through for 4-20 mA HART loop protocol field telemetry without inductive coupling.

Frequently Asked Questions

Q: Does the P0926JMA baseplate support hot-swapping of individual Field Bus Modules (FBMs)?

A: Yes, the backplane bus logic and connector pins allow live insertion and removal of individual FBM units without interrupting power or signal communication on adjacent operating slots.

Q: How is backplane power redundancy managed across the 8 slots of the P0926JMA?

A: The baseplate features integrated dual power distribution rails that route primary and secondary +5 VDC supply buses across all slots, ensuring continuous operation if one power feed degrades.

Field Installation Guidelines

  1. Mount the P0926JMA baseplate horizontally onto standard DIN rails, ensuring all retention clamps latch tightly against the rail base.
  2. Verify that adjacent baseplates connect via dedicated HDLC interface cables before applying system backplane power.
  3. Connect the primary system ground strap to the dedicated grounding stud on the baseplate frame to ensure full EMI/RFI shielding protection.
  4. Align module keyways before inserting FBM units into any of the 8 slots to prevent pin bending on the +5 VDC backplane connector headers.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more