Skip to content

What are you looking for?


You may also like

IC694MDL758 | GE Fanuc | PACSystems RX3i 12/24 VDC Output ModuleIC694MDL758 | GE Fanuc | PACSystems RX3i 12/24 VDC Output ModuleIC694MDL758 | GE Fanuc | PACSystems RX3i 12/24 VDC Output Module
IC694MDL758 | GE Fanuc | PACSystems RX3i 12/24 VDC Output Module
IC694MDL758 | GE Fanuc | PACSystems RX3i 12/24 VDC Output Module
IC694MDL758 | GE Fanuc | PACSystems RX3i 12/24 VDC Output Module

IC694MDL758 | GE Fanuc | PACSystems RX3i 12/24 VDC Output Module


Only 10 left - Selling fast

PRODUCT SKU : IC694MDL758

PRODUCT TYPE : Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694MDL758 output module from GE Fanuc PACSystems RX3i series is a high-density DC output unit designed for positive logic applications. With 32 points divided into two groups of sixteen, it provides reliable switching performance, optical isolation, and efficient current handling for industrial automation systems.

Technical Specifications

  • Manufacturer GE Fanuc

  • Product Line PACSystems RX3i

  • Product Number IC694MDL758

  • Product Type 12/24 VDC Output Module

  • Minimum CPU Version Required RX3i CPU v7.70

  • Rated Voltage 12–24 VDC, positive logic

  • Output Voltage Range 10.2–28.8 VDC

  • Outputs per Module 32 (two groups of 16)

  • Isolation (Field to Backplane & Frame Ground) 250 VAC continuous; 1500 VAC for 1 minute

  • Isolation (Group to Group) 50 VAC continuous; 500 VAC for 1 minute

  • Output Current per Point 0.5 A (pilot duty or resistive load)

  • Maximum Current per Group 8 A without ESCP trip

  • Power Consumption (Backplane) 250 mA max from 5 V bus

  • Power Consumption (User Supply) 33 mA per group at 24 VDC with all outputs ON; 20 mA per group at 12 VDC with all outputs ON

  • Inrush Current 5.4 A for 10 ms without ESCP trip

  • On-State Voltage Drop ≤ 0.3 VDC

  • Off-State Leakage Current ≤ 0.1 mA

  • Response Time (On/Off) ≤ 0.5 ms

  • Environmental Conditions Surrounding air temperature up to 60 °C; Pollution Degree 2 environments only

  • Number of Points 32

  • Points per Common 16

  • Weight 1.36 kg

Application Scenarios

  • High-density DC output control in manufacturing automation

  • Systems requiring fast response times and low leakage current

  • Industrial environments needing reliable isolation between groups

FAQ

Q: How many outputs are available on this module?  A: 32 outputs, divided into two groups of 16.

Q: What is the maximum current per output point?  A: 0.5 A per point.

Q: Does the module provide isolation between groups?  A: Yes, 50 VAC continuous isolation with 500 VAC withstand for one minute.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more