PRODUCT SKU : IC694MDL741

PRODUCT TYPE : DC Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694MDL741 discrete output module from GE Fanuc PACSystems RX3i series is a 16-point DC output unit designed for negative logic (sinking) applications. It delivers reliable 12/24 VDC switching, making it suitable for industrial automation tasks such as motor control, solenoid actuation, and indicator lighting. With robust isolation, fast response times, and efficient power consumption, this module ensures dependable performance in demanding environments.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: PACSystems RX3i

  • Part Number: IC694MDL741

  • Product Type: Discrete Output Module

  • Number of Channels: 16 outputs (two groups of 8)

  • Logic Type: Negative logic (sinking)

  • Rated Voltage: 12/24 VDC

  • Output Voltage Range: 12–24 VDC (+20%, -15%)

  • Output Current per Channel: 0.5 A maximum

  • Maximum Current per Group: 2 A

  • Voltage Drop (ON State): ≤ 0.5 V

  • Leakage Current (OFF State): ≤ 1 mA

  • Response Time: ≤ 2 ms (ON/OFF)

  • Isolation (Field to Backplane & Frame Ground): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Isolation (Group-to-Group): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Power Consumption: 110 mA @ 5 VDC (all outputs ON)

  • Mounting: RX3i baseplate slot

  • Lifecycle Status: Active

Application Scenarios

  • Motor control systems requiring negative logic outputs

  • Solenoid actuation in industrial machinery

  • Indicator lighting and signaling applications

  • Automation environments needing fast response and reliable isolation

FAQ

Q: How many outputs does this module provide?  A: 16 outputs, divided into two groups of eight.

Q: What logic type is supported?  A: Negative logic (sinking).

Q: What is the maximum current per channel?  A: 0.5 Amps per output point.

Q: What is the typical response time?  A: 2 milliseconds or less for both ON and OFF states.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more