Product Description

The IC694ALG392 analog output module from GE Fanuc PACSystems RX3i series provides eight channels of precise voltage and current outputs for process control and automation systems. Designed for reliable signal generation, it supports both 0–10 VDC and 0–20 mA ranges, with fast update rates to ensure accurate response in demanding applications.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: PACSystems RX3i

  • Part Number: IC694ALG392

  • Product Type: Analog Output Module

  • Number of Channels: 8 analog outputs

  • Supply Voltage: 24 VDC

  • Voltage Output Range: 0–10 VDC

  • Current Output Range: 0–20 mA

  • Update Rate: 8 ms for all channels

  • Accuracy: ±0.5% of full scale (typical)

  • Category: PLCs / Machine Control

  • Category: PLC Module / Rack

  • Weight: 0.66 lbs (0.30 kg)

  • Lifecycle Status: Active

Application Scenarios

  • Process industries requiring precise analog signal generation

  • Machine control systems needing multiple voltage and current outputs

  • Automation environments where fast update rates are critical

FAQ

Q: How many analog outputs are available?  A: 8 channels.

Q: What signal ranges are supported?  A: 0–10 VDC for voltage and 0–20 mA for current.

Q: What is the update rate?  A: 8 milliseconds for all channels.

Q: What is the supply voltage required?  A: 24 VDC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more