Product Details

The Honeywell 51308112-010, also cataloged as the 51308112 LCN Coaxial Cable Set, operates as a dedicated hardware component for high-frequency signal transmission and node-to-node telemetry within Honeywell Local Control Network (LCN) architectures.

Hardware Specifications

Parameter Specification
Model 51308112-010 (51308112)
Brand Honeywell
Dimensions Length: 10 m
Operating Temp -40 deg C to +85 deg C
Power Consumption Passive physical transmission media (0 W)
Cable Type RG11 coaxial cable with integrated ferrites
Impedance 75 ohms
Connectors SMA-type connectors
Replacement Part Replaces 51109181-010

4-20 mA HART Loop Protocol & Channel-to-Channel Isolation

The RG11 coaxial assembly provides physical layer data transport across Local Control Network nodes, linking process controllers and interface modules. Integrated ferrite cores maintain high-frequency common-mode noise suppression and cross-talk attenuation across adjacent signal conduits. The 75-ohm matched impedance shielding prevents signal reflection, ensuring uninterrupted pass-through telemetry for downstream control loops and field instrumentation running 4-20 mA HART loop protocol signaling.

Frequently Asked Questions

Q: Can the 51308112-010 coaxial cable be installed without the integrated ferrite suppressors?

A: No. The molded ferrite cores are factory-positioned on the RG11 cable sheath to suppress high-frequency EMI/RFI and maintain required network noise margins.

Q: Is the 51308112-010 backward compatible with older Honeywell LCN system hardware?

A: Yes. The 51308112-010 directly replaces legacy part number 51109181-010 without requiring adapter hardware or network reconfiguration.

Field Installation Guidelines

  1. Connector Torque: Align the SMA male connectors with the node interface port and hand-tighten, finishing with an engineered SMA torque wrench to avoid over-torquing.
  2. Bend Radius: Maintain a minimum static bend radius of 120 mm along the RG11 assembly to prevent dielectric deformation and impedance shifts.
  3. Cable Separation: Route the coaxial cable assembly in dedicated low-voltage instrument trays, maintaining a minimum 300 mm clearance from high-voltage AC cables.
  4. Ferrite Protection: Ensure integrated ferrite clamps remain uncrushed and secured against physical impact during tray pulling operations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more