Skip to content

What are you looking for?


You may also like

Honeywell CC-KFSVR5 51202353-210 Fiber Optic Extender Cable Rev AHoneywell CC-KFSVR5 51202353-210 Fiber Optic Extender Cable Rev AHoneywell CC-KFSVR5 51202353-210 Fiber Optic Extender Cable Rev A
Honeywell CC-KFSVR5 51202353-210 Fiber Optic Extender Cable Rev A
Honeywell CC-KFSVR5 51202353-210 Fiber Optic Extender Cable Rev A
Honeywell CC-KFSVR5 51202353-210 Fiber Optic Extender Cable Rev A

Honeywell CC-KFSVR5 51202353-210 Fiber Optic Extender Cable Rev A


Only 10 left - Selling fast

PRODUCT SKU : 51202353-210

PRODUCT TYPE : Fiber Optic Cables

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell CC-KFSVR5, also cataloged as the 51202353-210 Fiber Optic Extender Cable Rev A, operates as a dedicated hardware component for high-speed optical signal extension within Experion PKS Series C platforms.

Hardware Specifications

Parameter Specification
Model CC-KFSVR5 (51202353-210 Rev A)
Brand Honeywell
Origin USA
Dimensions Length: 5.0 m
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive optical transmission media (0 W)
Media Type Multi-mode optical fiber assembly
Connector Type Duplex optical connectors (Series C interface)
Cable Jacket Flame-retardant industrial polymer

4-20 mA HART Loop Protocol & Channel-to-Channel Isolation

The CC-KFSVR5 Rev A cable assembly connects Series C C300 controllers and optical interface modules to remote field termination bases, transmitting digital telemetry and pass-through signals for 4-20 mA HART loop protocol instruments. Total channel-to-channel isolation provided by the non-conductive dielectric fiber core renders the link immune to high-voltage ground loops, lightning surges, and radio frequency interference. Low signal attenuation ensures deterministic edge timing across the entire 5.0 m physical span.

Frequently Asked Questions

Q: What distinguishes Revision A (Rev A) of the 51202353-210 cable assembly from earlier build revisions?

A: Revision A features updated strain-relief boots and a reinforced outer jacket layer designed to improve mechanical endurance during tight cabinet routing.

Q: Can the 51202353-210 optical cable be connected directly to single-mode laser transceivers?

A: No. The assembly utilizes multi-mode fiber core geometry. Connecting multi-mode fiber to single-mode optics causes mode-field mismatch, high insertion loss, and communication drops.

Field Installation Guidelines

  1. Connector Protection: Keep protective dust covers on optical connectors until immediate insertion to prevent airborne dust particles from contaminating the fiber end-faces.
  2. Keyed Alignment: Insert the duplex connector housing into the Series C optical transceiver module, aligning the optical keying notch until the side retention clip engages.
  3. Routing Radius: Maintain a minimum static bend radius of 50 mm along cabinet wire raceways to prevent micro-bending signal loss.
  4. Mechanical Strain: Avoid bundling heavy copper field cables directly on top of the optical fiber line to prevent physical pinching or jacket deformation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more
Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

In industrial automation, connecting physical hardware with high-level software remains a primary operational challenge. Factories utilize programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and smart sensors from diverse vendors. These devices often speak different proprietary protocols. Open Platform Communications (OPC) servers solve this interoperability challenge by standardizing how data flows across factory networks.

Read more