Product Overview

The GE IS210MACCH2AGG functions as a high-speed communication backbone for the Mark VIe Speedtronic control system. This PCIe-based Network Interface Card (NIC) handles massive data throughput across the control network, supporting real-time synchronization between controllers and human-machine interfaces (HMI). By providing 10 Gbps connectivity, it ensures the control system maintains zero-latency data acquisition even in large-scale power plant architectures.

Technical Specifications

  • Manufacturer: General Electric (GE)

  • Series: Mark VIe

  • Product Type: Network Interface Card (NIC)

  • Bus Interface: PCI Express (PCIe) 3.0 x16

  • Network Speed: 10 Gigabit Ethernet (10GbE)

  • Data Transfer Rate: Up to 10 Gbps

  • Supported Protocols: TCP/IP, UDP, IPsec

  • Power Requirements: 5V DC (425 mA consumption)

  • Operating Temperature: 0°C to 60°C (32°F to 140°F)

  • Dimensions: 15.2 cm x 10.2 cm x 2.5 cm (6.0 x 4.0 x 1.0 inches)

  • Weight: 0.4 kg (0.88 lbs)

  • Condition: 100% Brand New Original

Engineering Advantages

  • High-Bandwidth Determinism: The 10GbE interface eliminates communication bottlenecks. It allows the Mark VIe system to transmit complex diagnostic packets and high-resolution trend data without impacting the primary control loop timing.

  • Hardware-Level Security: Integrated support for the IPsec protocol enables secure data encryption at the hardware level. This feature protects the control network from unauthorized access and data tampering in interconnected industrial environments.

  • Efficient Thermal Management: Despite the high data rate, the card consumes only 425 mA at 5V DC. This low power draw reduces heat dissipation within the PC enclosure, allowing for stable operation in standard industrial rack-mount servers without specialized cooling.

  • Seamless Integration: The PCIe 3.0 x16 form factor fits standard industrial computer backplanes. This compatibility simplifies hardware upgrades for existing Mark VIe workstations, enabling a direct transition to 10 Gigabit infrastructure.

FAQs

  • Does the IS210MACCH2AGG require specific drivers for Mark VIe HMIs?

    Yes. You must install the GE-approved driver package through ToolboxST to enable full 10GbE functionality. Using generic drivers may disable specific industrial protocol optimizations required for turbine control.

  • Can I install this card in a standard commercial server?

    While the IS210MACCH2AGG uses a standard PCIe 3.0 x16 interface, GE designs it specifically for the Mark VIe ecosystem. Ensure your server's BIOS and OS environment match the requirements specified in the GE Mark VIe control system documentation.

  • How does this card support redundant network configurations?

    Engineers typically install two IS210MACCH2AGG cards in a dual-bus configuration. This setup allows the Mark VIe system to utilize redundant Ethernet paths (Network A and Network B) for mission-critical reliability.

  • What is the "Brand New" guarantee for this product?

    We supply the IS210MACCH2AGG as 100% Brand New in original factory packaging. Each unit undergoes rigorous inspection to verify original serial numbers and firmware revisions, ensuring authentic E-E-A-T performance in your control rack.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more