Product Description

The IC697MDL671 is a 24 VDC interrupt input module designed for the GE Fanuc Series 90-70 PLC family. It provides 16 input points with robust isolation and fast response characteristics, making it suitable for industrial automation systems requiring precise interrupt-driven control.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: Series 90-70

  • Part Number: IC697MDL671

  • Product Type: Interrupt Input Module

  • Weight: 1.75 lbs (0.79 kg)

  • Rated Voltage: 24 VDC

  • Input Voltage Range: -3 to 30 VDC

  • Input Current: 10 mA typical

  • Required Current: 0.3 A

  • Number of Inputs: 16 channels per module

  • Isolation Voltage: 1500 V

  • ON-State Voltage: 13.5–30 VDC

  • OFF-State Voltage: -3 to 5 VDC (positive logic), -5 to 30 VDC (negative logic)

  • ON-State Current: 6–15 mA

  • OFF-State Current: 0–2 mA

Application Scenarios

  • Interrupt-Driven Control: Ideal for applications requiring precise event-driven input handling.

  • Industrial Automation: Supports Series 90-70 PLCs in manufacturing, process control, and monitoring systems.

  • High Reliability: Strong isolation ensures safe operation in demanding environments.

  • Legacy System Maintenance: Provides continued support for Series 90-70 installations.

FAQ

Q: How many inputs does the IC697MDL671 provide?  A: It offers 16 input channels per module.

Q: What is the rated operating voltage?  A: 24 VDC, with an input range of -3 to 30 VDC.

Q: What isolation level is provided?  A: 1500 V isolation between field and logic sides.

Q: Is the IC697MDL671 suitable for interrupt-driven applications?  A: Yes, it is specifically designed for interrupt input functionality.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more