Skip to content

What are you looking for?


You may also like

GE HE693DAC420 Series 90-30 Isolated Analog Output ModuleGE HE693DAC420 Series 90-30 Isolated Analog Output ModuleGE HE693DAC420 Series 90-30 Isolated Analog Output Module
GE HE693DAC420 Series 90-30 Isolated Analog Output Module
GE HE693DAC420 Series 90-30 Isolated Analog Output Module
GE HE693DAC420 Series 90-30 Isolated Analog Output Module

GE HE693DAC420 Series 90-30 Isolated Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : HE693DAC420

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE HE693DAC420, also cataloged as the HE693DAC420 Isolated Analog Current Output Module, operates as a dedicated hardware component for converting digital controller commands into 4-20 mA or 0-20 mA current loops within Series 90-30 PLC systems.

Hardware Specifications

Parameter Specification
Model HE693DAC420
Brand GE / GE Fanuc
Origin USA
Operating Temp 0 to 60 deg C
Power Consumption 90 mA @ 5 VDC / 120 mA @ 24 VDC
Number of Channels 4 Channels
Output Range 4-20 mA or 0-20 mA
Resolution 14 bits (13 bits plus sign D/A resolution)
Isolation 1500 VAC (RMS) Channel-to-Channel and Channel-to-Ground
Power Supply External 24 VDC User-Supplied Loop Power
Current Surge on Power-up 250 mA for 10 ms @ 5 VDC / 900 mA for 30 ms @ 24 VDC
Load Impedance Less than or equal to 1.1 kohm @ 24 V Loop Voltage
Maximum Linearity Error 0.10% Full Scale (4-20 mA) / 0.15% Full Scale (0-20 mA)
Relative Humidity 5% to 95%, non-condensing

Deterministic Networks and I/O Density Scaling

The HE693DAC420 module integrates into the Series 90-30 backplane to execute deterministic data updates from the main CPU card. High channel-to-channel and channel-to-ground isolation limits electrical noise propagation across the backplane bus interface, preserving communication velocity across expanded sub-rack configurations. Digital-to-analog processing pathways maintain firmware flash compatibility across standard Series 90-30 rack backplanes while providing stable current outputs under dynamic load resistance variations.

Frequently Asked Questions

Q: Does the HE693DAC420 require an external power source to drive the 4-20 mA loops?

A: Yes. The module relies on an external 24 VDC user-supplied power source to energize the isolated output loops in addition to the 5 VDC backplane logic draw.

Q: Can the HE693DAC420 module be installed or removed from the Series 90-30 rack while backplane power is active?

A: No. Power to the Series 90-30 rack must be completely isolated prior to inserting or removing the module to prevent electrical damage to backplane bus pins and internal D/A converter circuitry.

Field Installation Guidelines

  1. De-energize the Series 90-30 rack power supply and isolate external 24 VDC loop power before mounting or wiring the module.
  2. Slide the HE693DAC420 module firmly into the designated rack slot until the top and bottom retaining clips latch into the backplane baseplate.
  3. Wire the external 24 VDC field power supply to the terminal connector, maintaining correct polarity to support the internal isolation circuitry.
  4. Route 4-20 mA field current loop wiring using twisted-pair shielded cables to prevent inductive noise pickup from adjacent power lines.
  5. Ground all cable shields at a single Earth ground terminal near the panel entrance to avoid establishing ground loop currents.
  6. Verify that maximum loop resistance on each output channel does not exceed 1.1 kohms under 24 VDC operation before powering up the system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more