Skip to content

What are you looking for?


You may also like

GE IC695ALG708 PACSystems RX3i Analog Output ModuleGE IC695ALG708 PACSystems RX3i Analog Output ModuleGE IC695ALG708 PACSystems RX3i Analog Output Module
GE IC695ALG708 PACSystems RX3i Analog Output Module
GE IC695ALG708 PACSystems RX3i Analog Output Module
GE IC695ALG708 PACSystems RX3i Analog Output Module

GE IC695ALG708 PACSystems RX3i Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : IC695ALG708

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The IC695ALG708 from GE is a non-isolated 8-channel analog output module designed for RX3i PACSystems. It supports both voltage and current outputs with high-resolution performance and precise timing, making it suitable for applications requiring accurate analog control.

Technical Specifications

  • Module Type: Non-isolated analog output

  • Channels: 8

  • Voltage Output Range: 0–10 V, ±10 V

  • Current Output Range: 0–20 mA, 4–20 mA

  • Resolution:

    • ±10 V: 15.9 bits

    • 0–10 V: 14.9 bits

    • 0–20 mA: 15.9 bits

    • 4–20 mA: 15.6 bits

  • Maximum Load: 850 Ω

  • Data Format: Floating point IEEE 32-bit or 16-bit integer in 32-bit field

  • Update Rate: 8 ms (all channels)

  • Output Settling Time: 2 ms (0–95%)

  • Isolation Voltage (Field to Backplane): 2550 VDC for 1 second

  • Power Consumption: 375 mA at 3.3 VDC, 315 mA at 24 VDC

  • Maximum Module Power Dissipation: 7.25 W

  • External Supply Voltage: 19.2–30 V (24 V nominal)

  • External Current Input: 210 mA

  • HART Protocol: Not supported

Mechanical & Environmental

  • Weight: 0.94 lbs (0.43 kg)

  • Series: PACSystems RX3i

  • Operating Temperature: 0–60 °C

  • Power Dissipation (Vuser=24V): 7.25 W maximum

Applications

The IC695ALG708 is ideal for controlling analog devices such as actuators, valves, and control loops within RX3i automation systems where precise voltage and current output is required.

FAQ

  • Q: Can this module support HART communication?
    A: No, HART protocol is not supported.

  • Q: What is the maximum output load?
    A: 850 Ω for current and voltage outputs.

  • Q: Is the module hot-swappable?
    A: Yes, the RX3i backplane supports module replacement without powering down the system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more