PRODUCT SKU : IC694MDL930

PRODUCT TYPE : Relay Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694MDL930 relay output module from GE Fanuc PACSystems RX3i series provides sixteen individually isolated Form A (Normally Open) relay outputs. Designed for flexible AC/DC voltage operation, it supports a wide range of loads with strong isolation and long relay contact life. This module is ideal for industrial automation systems requiring reliable switching and robust performance.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: PACSystems RX3i

  • Part Number: IC694MDL930

  • Product Type: Relay Output Module

  • Number of Channels: 16 isolated relay outputs

  • Contact Form: Form A (Normally Open)

  • Operating Voltage Range: 5–30 VDC or 5–250 VAC

  • Nominal Output Voltage: 24 VDC; 120–240 VAC

  • Output Current per Channel:

    • Minimum: 10 mA

    • Maximum: 4 A resistive (5–30 VDC, 5–250 VAC)

    • Maximum: 200 mA resistive (125 VDC)

    • Pilot duty: 2 A per output (5–30 VDC, 5–250 VAC)

  • Maximum Load: 4 A resistive per output; 20 A maximum per module (UL installations)

  • Switching Current: 4 A per point

  • Inrush Current Rating: 5 A

  • Response Time: 10–15 ms typical

  • Relay Contact Life: 150,000–1,000,000 operations depending on load type

  • Isolation (Field to Backplane & Frame Ground): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Isolation (Point-to-Point): Yes

  • Backplane Current Draw: 6 mA at 5 VDC; 70 mA at 24 VDC relay power (all outputs ON)

  • LED Indicators: 32 individually numbered LEDs for output status

  • Compatible CPUs: PACSystems RX3i and Series 90-30

  • Installation: RX3i PACSystems PLC I/O slots

  • Weight: 0.88 lbs (0.40 kg)

  • Lifecycle Status: Active

Application Scenarios

  • Industrial automation systems requiring AC/DC relay switching

  • Applications needing isolated outputs for safety and reliability

  • Environments where pilot duty and lamp load switching are common

FAQ

Q: How many relay outputs does this module provide?  A: 16 individually isolated Form A (Normally Open) relay outputs.

Q: What voltage ranges are supported?  A: 5–30 VDC and 5–250 VAC.

Q: What is the maximum switching current?  A: 4 Amps per point for resistive loads.

Q: What is the expected relay contact life?  A: Between 150,000 and 1,000,000 operations depending on voltage and load type.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more