PRODUCT SKU : IC694MDL740

PRODUCT TYPE : DC Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694MDL740 discrete output module from GE Fanuc PACSystems RX3i series is engineered for reliable DC output switching in industrial automation. Supporting positive logic configuration, it provides sixteen outputs arranged into two groups of eight. With robust isolation, fast response times, and diagnostic LED indicators, this module ensures dependable performance in demanding control environments.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: PACSystems RX3i

  • Part Number: IC694MDL740

  • Product Type: Discrete Output Module

  • Number of Channels: 16 outputs (two groups of 8)

  • Nominal Output Voltage: 12/24 VDC

  • Voltage Range: 12–24 VDC (+20%, -15%)

  • Logic Type: Positive logic

  • Output Current per Channel: 0.5 A

  • Output Current per Module: 2 A maximum

  • On-State Voltage: 11.5–30 VDC

  • Off-State Voltage: 0–5 VDC

  • On-State Current: 3.2 mA

  • Off-State Current: ≤ 1 mA

  • Response Time: 2 ms typical, 2 ms maximum (on/off)

  • Output Voltage Drop: ≤ 1.0 V

  • Maximum Inrush Current: 4.78 A for 10 ms

  • Isolation (Field to Backplane & Frame Ground): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Isolation (Group to Group): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Power Consumption: 110 mA from 5 VDC bus (all outputs ON)

  • LED Indicators: Yes, for output status monitoring

  • Weight: 0.69 lbs (0.31 kg)

  • Lifecycle Status: Active

Application Scenarios

  • Industrial automation systems requiring grouped DC outputs

  • Machine control environments needing fast response and reliable isolation

  • Applications where diagnostic LEDs and hot-swappable modules improve maintenance efficiency

FAQ

Q: How many outputs are available on this module?  A: 16 outputs, divided into two groups of eight.

Q: What is the maximum current per output point?  A: 0.5 Amps per channel.

Q: Does the module provide isolation between groups?  A: Yes, 250 VAC continuous isolation with 1500 VAC withstand for one minute.

Q: What is the typical response time?  A: 2 milliseconds for both on and off states.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more