Product Description

The IC694CHS398 is a serial expansion backplane from GE Fanuc Emerson, designed specifically for the RX3i PACSystem. This module provides seamless integration and connectivity to enhance the capabilities of the system, allowing up to 5 expansion slots for additional modules. The IC694CHS398 is built with reliable performance and flexible installation options to meet demanding industrial automation needs.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Type: Serial Expansion Backplane

  • Part Number: IC694CHS398

  • Product Line: RX3i PACSystem

  • Weight: 1.25 lbs (0.57 kg)

  • UPC: 0 799705793422

Key Features

  • Number of Slots: 5 expansion slots

  • Operating Voltage: 5 VDC

  • Internal Current Draw: 170 mA

  • Power Consumption: 0.85 W

  • Operating Temperature Range: 0°C to 40°C (32°F to 104°F)

  • Storage Temperature Range: 0°C to 40°C (32°F to 104°F)

  • Operating Humidity: Up to 80% (Non-Condensing)

  • Storage Humidity: Up to 80% (Non-Condensing)

  • Installation Altitude: Up to 1000 meters above sea level

Applications and Use Cases

The IC694CHS398 backplane is ideal for systems that require serial communication and flexible expansion. Its robust design ensures stability across a wide range of operating conditions, from temperature extremes to high humidity environments. Perfect for industrial control systems, PLC systems, and automation networks, this expansion backplane supports the needs of modern manufacturing environments.

FAQ

Q: How many slots does the IC694CHS398 support for expansion modules?
A: The IC694CHS398 provides 5 slots for module expansion, enhancing the versatility of the system.

Q: What is the operating temperature range for this backplane?
A: The backplane operates within a temperature range of 0°C to 40°C.

Q: Can this backplane be installed at higher altitudes?
A: Yes, the IC694CHS398 is rated for installation at altitudes up to 1000 meters above sea level.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more