Skip to content

What are you looking for?


You may also like

GE Fanuc IC670ALG230 8-Point Analog Current Source Input ModuleGE Fanuc IC670ALG230 8-Point Analog Current Source Input ModuleGE Fanuc IC670ALG230 8-Point Analog Current Source Input Module
GE Fanuc IC670ALG230 8-Point Analog Current Source Input Module
GE Fanuc IC670ALG230 8-Point Analog Current Source Input Module
GE Fanuc IC670ALG230 8-Point Analog Current Source Input Module

GE Fanuc IC670ALG230 8-Point Analog Current Source Input Module


Only 10 left - Selling fast

PRODUCT SKU : IC670ALG230

PRODUCT TYPE : Discrete Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The GE Fanuc IC670ALG230 is an 8-point analog current source input module engineered for the Field Control system. It enables precise current signal acquisition from sensors and transmitters in process automation environments. Each channel supports high-resolution current measurement, allowing accurate analog data conversion for industrial control applications.

Designed for versatility, the module can operate from a 24V DC backplane supply or an isolated external power source. Its diagnostic LED indicators simplify troubleshooting and system monitoring. With a compact design and durable build, it is ideal for distributed control architectures that demand stable and noise-resistant analog input performance.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Model Number: IC670ALG230

  • Product Type: 8-Point Analog Current Source Input Module

  • Product Line: Field Control

  • Number of Input Channels: 8

  • Input Signal Type: Current source

  • Input Range: 0 to 20 mA (default)

  • Resolution: 12-bit unscaled data

  • Conversion Time: 1.5 ms per channel

  • Accuracy: ±0.1% of full scale at 25°C

  • Input Impedance: 250 ohms per channel

  • Power Supply Options: 24V DC backplane power or isolated external source

  • Configuration Method: Via Genius Bus Interface Unit (BIU)

  • Front Panel Indicators: Diagnostic LED for status and fault detection

  • Operating Temperature Range: 0°C to 60°C

  • Storage Temperature Range: -40°C to 85°C

  • Relative Humidity: 5% to 95% non-condensing

  • Dimensions: 4.3 in (H) x 3.5 in (W) x 2.0 in (D)

  • Weight: 0.5 lb (0.23 kg)

Key Features

  • Eight precision analog current input channels for high-performance signal acquisition

  • 12-bit data resolution for accurate process measurement

  • Configurable operation via Genius BIU for flexible control integration

  • Optional isolated power input enhances signal stability and reduces interference

  • LED indicators for quick diagnostics and module status

  • Supports 0–20 mA current loops for standard industrial transmitters

  • Compact, modular design for easy installation in Field Control racks

Applications

  • Process and factory automation systems

  • Industrial data acquisition and control

  • Sensor and transmitter current signal monitoring

  • Distributed control systems (DCS)

  • Equipment requiring analog current loop integration

FAQ

Q1: What type of signals does the IC670ALG230 accept?
It supports analog current input signals within the 0 to 20 mA range.

Q2: How is the module powered?
It can draw 24V DC power from the Field Control backplane or use an external isolated 24V DC supply for enhanced noise immunity.

Q3: Can the module be configured remotely?
Yes, configuration is managed via the Genius Bus Interface Unit (BIU).

Q4: Is calibration required?
Factory calibration ensures long-term accuracy; however, periodic verification is recommended for precision applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more