Skip to content

What are you looking for?


You may also like

FC‑TSRO‑0824 | Honeywell Digital Output Field Termination ModuleFC‑TSRO‑0824 | Honeywell Digital Output Field Termination ModuleFC‑TSRO‑0824 | Honeywell Digital Output Field Termination Module
FC‑TSRO‑0824 | Honeywell Digital Output Field Termination Module
FC‑TSRO‑0824 | Honeywell Digital Output Field Termination Module
FC‑TSRO‑0824 | Honeywell Digital Output Field Termination Module

FC‑TSRO‑0824 | Honeywell Digital Output Field Termination Module


Only 10 left - Selling fast

PRODUCT SKU : FC-TSRO-0824

PRODUCT TYPE : Digital Output Termination Assembly

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell FC‑TSRO‑0824 Digital Output Field Termination Assembly is designed as a reliable interface between system interconnection cables and external field wiring. Built to meet IEC 61508 SIL3 safety requirements, it provides independent, floating output contacts with integrated relay and fuse protection, ensuring safe and flexible wiring configurations in safety‑critical applications.

Technical Specifications

  • Model / Type Numbers: FC‑TSRO‑0824 V1.1, FS‑TSRO‑0824 V1.1

  • Manufacturer: Honeywell

  • Type: Digital Output Field Termination Assembly

  • Safety Class: SIL3 compliant

  • Nominal Input Voltage: 24 VDC

  • Maximum Input Voltage: 36 VDC

  • Relay Pick‑up Voltage: 19.2 VDC

  • Input Current: ~40 mA at 24 VDC

  • Output Channel Design:

    • Three relays per channel

    • Fused NO field contact (5 AT, slow‑acting)

    • Status indication LED

  • Contact Type: Floating, non‑commoned, independently wired outputs

  • Fuse Rating: 5 A (slow‑acting blade type)

  • Warranty: 12 months standard coverage

Key Features

  • Independent Outputs: Floating contacts allow flexible wiring without shared common points

  • Integrated Protection: Each channel includes fused NO contacts for circuit safety

  • Status Indication: LED indicators provide clear channel monitoring

  • SIL3 Certification: Meets IEC 61508 requirements for functional safety

  • Robust Design: Built for long‑term reliability in industrial environments

Application Scenarios

  • Safety‑critical digital output interfacing in Honeywell Safety Manager systems

  • Emergency shutdown systems (ESD) requiring SIL3 compliance

  • Process control environments with independent relay outputs

  • Industrial automation requiring fused and monitored digital outputs

FAQ

Q: What makes the FC‑TSRO‑0824 suitable for SIL3 applications?  A: It complies with IEC 61508 SIL3 standards, offering independent relay outputs, fuse protection, and diagnostic LEDs.

Q: Can the outputs be wired independently?  A: Yes, each channel has floating, non‑commoned contacts that can be wired separately.

Q: How does this module differ from standard output assemblies?  A: Unlike conventional assemblies, it integrates three relays per channel, fused contacts, and LED status indicators for enhanced safety monitoring.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more