PRODUCT SKU : F2DO1601

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The HIMA F2DO1601/F2 DO 16 01 is a high-performance digital output module engineered for the HIMatrix F2 series. It delivers precise and reliable output control for diverse industrial automation and process control applications. Designed for compact installation, the module combines high-density output channels with robust industrial durability.

Technical Specifications

  • Manufacturer: HIMA

  • Model Number: F2DO1601/F2 DO 16 01

  • Product Type: Safety-Related Digital Output Module

  • Output Channels: 16

  • Output Type: Transistor output

  • Output Voltage: 24 V DC

  • Output Current: 0.5 A per channel

  • Response Time: <10 ms

  • Isolation: Galvanic isolation between channels

  • Operating Temperature Range: -20°C to +60°C

  • Dimensions (L × W × H): 140 × 120 × 75 mm

  • Weight: 0.5 kg

  • Protection Class: IP20

Key Features

  • High-density 16-channel output for extensive control capabilities

  • Rapid switching with response times under 10 milliseconds

  • Robust design ensures long-term reliability in harsh industrial environments

  • Versatile output configurations to meet varied application requirements

  • Compact footprint for efficient panel integration

Application Scenarios

The HIMA F2DO1601/F2 DO 16 01 is ideal for:

  • Process control systems requiring reliable digital outputs

  • Automation networks utilizing HIMatrix F2 series modules

  • Safety-related control tasks in industrial and manufacturing settings

  • Systems where fast response and durable outputs are essential

FAQ

Q: How many outputs does the F2DO1601 provide?
A: The module provides 16 independent transistor outputs.

Q: What is the operating voltage range?
A: The module operates at 24 V DC with 0.5 A per channel.

Q: Is this module suitable for harsh environments?
A: Yes. The F2DO1601 is designed for industrial conditions and provides IP20 protection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more