Overview
The Prosoft 5204-DFNT-PDPM (Version 2.45, OS 2.41) is a versatile EtherNet/IP to PROFIBUS DPV1 master gateway designed to integrate PROFIBUS DP slave devices into industrial automation systems. It enables seamless communication between EtherNet/IP networks and PROFIBUS DP devices, supporting both client and server communication modes. The compact DIN-rail mount design ensures easy installation in control cabinets while maintaining robust connectivity and performance.

Technical Specifications

  • Brand / Model: Prosoft 5204-DFNT-PDPM

  • Communication Type: EtherNet/IP to PROFIBUS DPV1 Master Gateway

  • EtherNet/IP Support: Explicit Messaging, 100/1000-word data table file size

  • PROFIBUS DPV1 Support: Up to 125 slave devices, 1536 bytes I/O (768 words), baud rates up to 12 Mbps

  • Hardware Requirements: Power 24 VDC (range 18–32 VDC), Max current 500 mA

  • Operating Temperature: -20°C to 50°C

  • Physical Dimensions: 5.20 in (H) x 2.07 in (W) x 4.52 in (D)

  • Mounting Style: DIN-rail

  • PROFIBUS Port: Configurable DB9F connector

  • Protocol Support: ProLinx Protocol for seamless EtherNet/IP integration

  • Version: Firmware 2.45, OS 2.41

Applications

  • Integration of PROFIBUS DP slave devices into EtherNet/IP-based industrial networks

  • Gateway solution for factory automation, process control, and distributed systems

  • Ideal for upgrading legacy PROFIBUS devices to EtherNet/IP communication

FAQ

  • Q: How many PROFIBUS DP slave devices can the gateway support?
    A: Up to 125 slaves with 1536 bytes of I/O

  • Q: What EtherNet/IP features are supported?
    A: Explicit Messaging with 100/1000-word data table support

  • Q: Can it be mounted on a standard DIN-rail?
    A: Yes, the unit is DIN-rail mountable for easy installation

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more