Product Details

Configured for fiber-optic signal extension in safety-rated network architectures, the Emerson VS6002 (KJ2221X1-EA1 SISNet Repeater) provides direct physical/electrical execution of redundant communication data regeneration and optical-to-electrical conversion.

Hardware Specifications

Parameter Specification
Model VS6002 (KJ2221X1-EA1)
Brand Emerson
Origin USA
Weight Not specified
Dimensions Standard SISNet repeater form factor
Operating Temp -40 deg C to +70 deg C
Power Consumption 0.3 A @ 24 VDC
Communication Type Fiber-optic redundant
Nodes Supported Up to 32

SIS: Fail-Safe State Execution

The VS6002 operates as a component of the safety-rated SISNet, facilitating deterministic communication across distributed safety controllers. In the event of network disruption or optical path failure, the repeater architecture ensures that the system maintains a predefined fail-safe state, preventing the propagation of corrupted data packets that could lead to unauthorized safety function activation. The module is engineered with inherent logic to detect signal attenuation or loss of link, immediately signaling the safety controllers to enter a safe mode. This functionality is supported by the 50 ms update time constraint, ensuring that timing requirements for critical safety loop closure are strictly observed across all 32 supported network nodes.

Frequently Asked Questions (FAQ)

Q: Can this repeater be used in a simplex communication setup?

A: The VS6002 is designed for redundant communication paths. While it can physically function in varied configurations, the redundant architecture is required to meet the safety integrity level (SIL) requirements of the SISNet platform.

Q: What is the maximum update time for the network?

A: The repeater ensures an update time of 50 ms for any data packet transmitted across the SISNet. This performance is deterministic and must be accounted for when calculating total loop response times within the safety logic.

Field Installation Guidelines

  • Mounting: Install the VS6002 in a protected cabinet environment that meets ISA-S71.04-1985 Class G3 standards. Use the provided DIN-rail mounting clips to ensure vibration resistance up to 0.5 g.

  • Fiber Optic Handling: Clean optical connectors using approved industrial solvent and lint-free wipes prior to insertion. Avoid exceeding the minimum bend radius of the fiber-optic cabling to prevent signal attenuation and data loss.

  • Grounding: Terminate the module chassis to the cabinet grounding bus using a low-impedance braided strap. Proper grounding is necessary to minimize electromagnetic noise and to maintain compliance with surge protection limits.

  • Verification: Following installation, perform a link test via the safety workstation to confirm signal strength and error-free communication between all nodes. Ensure that the 24 VDC power supply is stable and within the 300 mA maximum current draw to prevent intermittent signal dropouts.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more