The Emerson 396571-02-6, also cataloged as the 396571 Isolated Input Module, operates as a dedicated hardware component for galvanic signal conditioning and field contact state detection within ControlWave PLC platforms. Equipped with a 24 V local connector and an integrated LED daughterboard, it processes field input signals while maintaining electrical isolation from internal backplane logic.

Hardware Specifications

Parameter Specification
Model 396571-02-6
Brand Emerson
Base Model 396571
Origin USA
Weight 0.26 lbs (approx. 0.12 kg)
Dimensions Standard ControlWave Micro Module Footprint
Operating Temp -40 to 70 deg C
Power Consumption 24 VDC Local Connector Powered
Signal Isolation Isolated Field Circuits
Local Indication Onboard LED Daughterboard
System Compatibility ControlWave PLC Series

4-20 mA HART Loop Protocol and Channel Isolation

The 396571-02-6 module incorporates optical channel-to-channel isolation architecture to decouple field-side transients from the internal system bus. This isolation structure suppresses common-mode voltage spikes, ground loops, and electrical cross-talk, preventing signal degradation across neighboring analog circuits running 4-20 mA HART loop protocol signals on the same backplane assembly.

Frequently Asked Questions

Q: What function does the integrated LED daughterboard serve on the 396571-02-6 module?

A: The onboard LED daughterboard provides real-time local visual status indication for channel input state activity and diagnostic hardware conditions.

Q: How is local power supplied to the input circuitry of the 396571-02-6?

A: The module utilizes a dedicated 24 V local connector interface to deliver isolated operating voltage directly to field input sensing circuits.

Q: Can the 396571-02-6 module be hot-swapped during system operation?

A: Hot-swapping limits depend on the specific ControlWave rack chassis configuration; field power to the 24 V local connector should be isolated prior to module removal to avoid arc discharge.

Field Installation Guidelines

  1. Power down field-side 24 V power connections before seating or unseating the module from the ControlWave backplane chassis.
  2. Align the module circuit board with the chassis guide rails and push firmly until the backplane connector engages completely.
  3. Tighten the retaining panel fasteners to establish frame grounding contact and secure the assembly against vibration.
  4. Wire 24 V local input power and field signal leads to the designated terminal header, ensuring proper polarity.
  5. Ground field cable shielding at a single grounding point on the enclosure chassis to minimize electromagnetic noise coupling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more