Skip to content

What are you looking for?


You may also like

DS200LDCCH1ALA | General Electric | Drive Control/LAN Communications BoardDS200LDCCH1ALA | General Electric | Drive Control/LAN Communications BoardDS200LDCCH1ALA | General Electric | Drive Control/LAN Communications Board
DS200LDCCH1ALA | General Electric | Drive Control/LAN Communications Board
DS200LDCCH1ALA | General Electric | Drive Control/LAN Communications Board
DS200LDCCH1ALA | General Electric | Drive Control/LAN Communications Board

DS200LDCCH1ALA | General Electric | Drive Control/LAN Communications Board


Only 10 left - Selling fast

PRODUCT SKU : DS200LDCCH1ALA

PRODUCT TYPE : CPU Processors

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The General Electric DS200LDCCH1ALA, also cataloged as the DS200LDCCH1ALA Drive Control/LAN Communications Board, operates as a dedicated hardware component for multi-processor I/O coordination and network data exchange within Mark V drive control system platforms.

Hardware Specifications

Parameter Specification
Model DS200LDCCH1ALA
Brand General Electric
Processor Architecture 4 (DCP, LCP, MCP, CMP)
Interface Support DLAN+, Genius, CPL, C-Bus

Industrial Control and Drive Systems

The DS200LDCCH1ALA utilizes backplane bus communication velocity to synchronize multi-processor I/O operations. The module facilitates I/O density scaling by employing four dedicated microprocessors: the DCP for analog/digital filtering, the LCP for network traffic management, and the MCP/CMP pair for motor control computations. Firmware flash compatibility supports logic-level adjustments for various protocols, including DLAN+ and Genius interfaces. Integration into DIRECTO-MATIC 2000 systems requires adherence to deterministic network timing; external terminal boards, such as the DS200ADCI, are required for CPL and C-Bus differential signaling to maintain bus integrity.

Frequently Asked Questions (FAQ)

Q: Are additional hardware modules required for specific bus system compatibility?

A: Yes. When interfacing with Genius, CPL, or C-Bus protocols, an optional DS200ADCI terminal board is required to support the specific physical layer requirements of these differential bus systems.

Q: What is the function of the onboard RESET button?

A: The physical RESET button is provided to clear operational faults and force a processor re-initialization sequence, which is used to recover the module from specific logic hang conditions without a full power cycle.

Field Installation Guidelines

  • Processor Initialization: Upon system activation, verify the DCP and LCP status indicators. If the LCP fails to filter LAN signals, inspect the communication cabling and ensure correct protocol settings via the firmware configuration.
  • Component Handling: The PCB is treated with conformal coating. Do not apply solvents to the surface during cleaning, as this may degrade the protective layer. Use only ESD-safe brushes for particulate removal.
  • Bus Termination: When utilizing C-Bus or CPL interfaces, verify that the differential bus is properly terminated at the end-of-line nodes to prevent signal reflections that can corrupt digital communication.
  • Keypad Interface: The attachable alphanumeric keypad must be seated firmly onto the board header. Ensure the ribbon cable is routed to prevent strain on the connector pins, as intermittent connections will result in input errors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more