The ABB CM572-DP, also cataloged as the CM572-DP Communication Module, operates as a dedicated hardware component for PROFIBUS DP master/slave communication processing within AC500 PLC platforms.

Hardware Specifications

Parameter Specification
Model CM572-DP
Brand ABB
Origin China
Weight 0.12 kg (0.26 lbs) gross weight
Dimensions Standard AC500 communication module footprint
Operating Temp 0 to 60 deg C
Power Consumption Powered via AC500 CPU terminal base bus
Network Interface PROFIBUS DP (RS-485 physical layer via 9-pin Sub-D female connector)
Protocol Support PROFIBUS DP-V0 / DP-V1 master and slave configurations
Transmission Rate 9.6 kbps to 12 Mbps (auto-baud rate detection)
Target System ABB AC500 PLC series

Backplane Bus Communication Velocity & Profinet / EtherNet/IP Deterministic Networks

The CM572-DP processes fieldbus cycles independently of the central processing unit, executing cyclic data exchange up to 12 Mbps to maintain backplane bus communication velocity across the AC500 I/O structure. Firmware flash compatibility allows seamless integration with ABB Automation Builder software, enabling synchronization between PROFIBUS field devices and Ethernet-based deterministic networks without inducing latency on the main processor.

Frequently Asked Questions

Q: How does the CM572-DP draw operating power within an AC500 rack assembly?

A: The module snaps directly onto an AC500 communication terminal base (such as TU515 or TU516) and receives its operating logic power via the internal CPU baseboard extension bus.

Q: What transmission speeds are supported on the PROFIBUS DP interface?

A: The hardware supports standard PROFIBUS DP baud rates ranging from 9.6 kbps up to 12 Mbps with automatic baud rate detection.

Q: Can multiple CM572-DP modules be installed on a single AC500 CPU base?

A: Yes, depending on the slot capacity of the specific CPU terminal base utilized, multiple communication modules can be mounted concurrently to support separate fieldbus segments.

Field Installation Guidelines

  1. Ensure main AC500 CPU power and field voltage supplies are disconnected before installing or removing communication modules.
  2. Align the CM572-DP module with the dedicated communication slot on the AC500 terminal base.
  3. Press the unit firmly onto the base connection header until the side retention locking tabs click into position.
  4. Attach a shielded RS-485 PROFIBUS cable with standard DB9 connectors, verifying that termination resistors are switched ON at both physical ends of the network segment.
  5. Ground the cable shield to the cabinet earthing rail using low-impedance ground clamps to prevent electromagnetic noise interference on high-speed serial signals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more