DC 732F 3BDH000375R0005 Digital Input/Output Module | ABBDC 732F 3BDH000375R0005 Digital Input/Output Module | ABBDC 732F 3BDH000375R0005 Digital Input/Output Module | ABB
DC 732F 3BDH000375R0005 Digital Input/Output Module | ABB
DC 732F 3BDH000375R0005 Digital Input/Output Module | ABB
DC 732F 3BDH000375R0005 Digital Input/Output Module | ABB

DC 732F 3BDH000375R0005 Digital Input/Output Module | ABB


Only 10 left - Selling fast

PRODUCT SKU : DC 732F 3BDH000375R0005

PRODUCT TYPE : Digital Input/Output Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB DC 732F 3BDH000375R0005, also cataloged as the DC 732F Digital Input/Output Module, operates as a dedicated hardware component for multi-channel discrete signal acquisition and field actuator driving within Freelance S700 I/O system platforms. Equipped with 32 non-redundant configurable digital input/output channels, the unit processes voltage levels with logical "0" defined from -30 V to +5 V and logical "1" from +13 V to +30 V. Powered by an external 24 VDC source drawing 0.15 A with a maximum power dissipation of 6 W, the 125 g module supports field cable runs up to 1000 m shielded or 600 m unshielded.

Hardware Specifications

Parameter Specification
Model DC 732F (3BDH000375R0005)
Base Model DC 732F
Brand ABB
Origin Sweden
Weight 125 g
Dimensions 67.5 mm x 54 mm x 76 mm (W x H x D)
Operating Temp -20 deg C to +60 deg C
Power Consumption 6 W max power dissipation (0.15 A at 24 VDC external)
Number of Channels 32 channels
Signal Type Digital Input/Output
Input Voltage Range "0" -30 V to +5 V
Input Voltage Range "1" +13 V to +30 V
Common Mode Voltage 24 VDC
Max Field Cable Length 1000 m (shielded), 600 m (unshielded)
Mechanical Form Factor S700 module housing
Status Diagnostics 40 front LEDs for signal status and error indication

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The digital module interfaces directly with the S700 backplane bus to ensure rapid backplane bus communication velocity during full 32-channel scan updates. High-density discrete routing enables high I/O density scaling within space-constrained cabinets without increasing local bus latency. Controller firmware flash compatibility allows online parameter loading and diagnostic configuration changes directly across the backplane interface, maintaining synchronization between field status registers and the main CPU loop.

Frequently Asked Questions

Q: How do the front status LEDs indicate signal states across the digital channels?

A: A yellow LED is dedicated to each individual channel, illuminating continuously whenever the corresponding input or output channel registers a high signal state (signal 1).

Q: What are the cable length limits for shielded versus unshielded field wiring connections?

A: Shielded field cables may extend up to 1000 m in length, while unshielded field wiring must not exceed 600 m to prevent excessive signal attenuation and noise interference.

Field Installation Guidelines

  • Lock the module onto the corresponding S700 terminal base unit until the mechanical mounting clips firmly snap in place.
  • Verify that the external 24 VDC power supply circuit is de-energized before connecting power terminal wires.
  • Route field input and output wiring away from high-voltage AC conductors to minimize electromagnetic noise coupling.
  • Connect shielded cable braids directly to the enclosure ground terminal bar using low-impedance grounding clamps.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more