Skip to content

What are you looking for?


You may also like

CENTUM Systems | Yokogawa | AAM11 Current/Voltage Input ModuleCENTUM Systems | Yokogawa | AAM11 Current/Voltage Input ModuleCENTUM Systems | Yokogawa | AAM11 Current/Voltage Input Module
CENTUM Systems | Yokogawa | AAM11 Current/Voltage Input Module
CENTUM Systems | Yokogawa | AAM11 Current/Voltage Input Module
CENTUM Systems | Yokogawa | AAM11 Current/Voltage Input Module

CENTUM Systems | Yokogawa | AAM11 Current/Voltage Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAM11

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Yokogawa AAM11 is a versatile analog input module engineered for the CENTUM CS and CENTUM VP distributed control systems. It serves as a critical interface, converting standard industrial analog signals—specifically current and voltage—into digital data for precise process monitoring and control. Designed for flexibility, the AAM11 allows engineers to configure inputs for either 4-20 mA current loops or 1-5 V voltage signals, making it a fundamental component for connecting a wide variety of field transmitters to the control system with high accuracy and reliability.

Technical Specifications

The AAM11 is built to deliver high-precision signal conversion in a compact form factor suitable for dense control panels.

Parameter Specification
Product Type Current/Voltage Input Module
Model Number AAM11
Compatible Systems CENTUM CS, CENTUM VP
Input Signal Types Current (4-20 mA) and Voltage (1-5 V)
Signal Conversion High-accuracy Analog-to-Digital
Configurability Software configurable for current or voltage
Dimensions 3.0" x 1.0" x 7.0" (7.6 cm x 2.5 cm x 17.8 cm)
Weight 0.1 kg (4.0 oz)

Model Code Interpretation

For Yokogawa modules, the suffix code is critical as it defines the specific communication protocol support and physical interface.

Part Number: AAM11

AAM11-AXX

  • A (Base Model): The standard AAM11 typically supports standard analog inputs.

  • Suffix Variations (e.g., AAM11B):

    • -B: Often denotes support for the BRAIN protocol, allowing for digital communication with intelligent field devices.

    • -S1 / -S2: These suffixes usually indicate specific hardware revisions or regional specifications (e.g., specific compliance standards).

    • Note: Always verify the specific suffix on the module label to ensure it meets the communication protocol requirements of your field devices (Standard Analog vs. BRAIN Protocol).

Installation and Wiring Guidelines

To ensure accurate signal acquisition and system stability, follow these installation practices:

  1. Carrier Compatibility: The AAM11 is designed to mount into specific I/O carrier boxes (such as the AAM series carriers). Ensure the module is fully inserted into the slot and the locking mechanism is engaged to secure the connection to the backplane.

  2. Signal Configuration:

    • Current Input (4-20 mA): Ensure the loop polarity is correct. The module typically provides a 250 Ω input impedance for current signals.

    • Voltage Input (1-5 V): When wiring for voltage, ensure the input impedance (typically 1 MΩ) is accounted for in your load calculations.

  3. Wiring Connections: Use shielded twisted-pair cables to minimize electromagnetic interference (EMI). Connect the shield to the ground terminal at the cabinet end to prevent noise from affecting the analog-to-digital conversion accuracy.

  4. Environmental Limits: Install the module in a control cabinet that maintains an ambient temperature within the standard industrial range (typically -20°C to +60°C) to prevent overheating.

Frequently Asked Questions (FAQ)

Q: What is the primary function of the AAM11?A: The AAM11 acts as an analog input interface. It accepts standard industrial signals (4-20 mA or 1-5 V) from field transmitters and converts them into digital data that the CENTUM control system can process.

Q: Can the AAM11 handle both current and voltage inputs?

A: Yes, the module is configurable. It can be set up to accept either 4-20 mA current signals or 1-5 V voltage signals, providing flexibility for different sensor types.

Q: Is the AAM11 compatible with CENTUM VP?

A: Yes, the AAM11 is fully compatible with both CENTUM CS and the newer CENTUM VP systems, allowing for seamless integration and hardware upgrades.

Q: What is the difference between AAM11 and AAM11B?

A: The standard AAM11 is typically used for standard analog signals. The AAM11B version usually includes support for the BRAIN protocol, which allows for digital communication and diagnostics with intelligent Yokogawa field devices.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




  • 5 stars: 5 (100%)
  • 4 stars: 0 (0%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
J
Julian

Impressed with the build quality. These AAM11 units feel durable and fit perfectly into our existing carrier boxes. They have been running stable under 24/7 load for two weeks now without a single signal drift. Great technical support during the procurement process.

S
Sarah

Finally found a reliable supplier for these legacy components. The AAM11 modules were in stock, and the team was super helpful in confirming the correct suffix for our specific BRAIN protocol requirements. Will definitely be ordering from them for our upcoming plant upgrade.

T
Thomas

Good quality, reliable performance. The modules work exactly as described in the technical manual. We integrated them into our CENTUM VP setup without any hiccups. Shipping was decent, though it took an extra day due to customs. Overall, a very reliable source for Yokogawa hardware.

E
Elena

Solid product. We use these for both 4-20 mA and 1-5 V loops, and the AAM11 modules handle the conversion with great precision. The flexibility to software-configure the inputs saved us a lot of time during commissioning. No issues with noise or interference after proper grounding.

M
Marcus

Excellent service from this supplier. We had an urgent need to replace a failing I/O module in our CENTUM CS system, and they expedited the shipping to get it to us in just two days. The AAM11 arrived perfectly packaged and passed our signal calibration tests on the first try. Highly professional!

Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more