Overview

The Honeywell CC-TAOX51 is a 16-channel analog output module designed to deliver precise 4–20 mA current signals for process control systems. It provides reliable output under harsh industrial conditions, supporting DIN-rail mounting and seamless integration with Honeywell controllers. The module is engineered for stable performance across wide temperature and vibration ranges.

Technical Specifications

  • Model Number: CC-TAOX51

  • Number of Channels: 16

  • Output Type: 4–20 mA analog current

  • Power Supply: 24 VDC

  • Mounting: DIN rail compatible

  • Operating Temperature: -40 °C to +70 °C

  • Storage/Transport Temperature: -40 °C to +85 °C

  • Permissible Humidity (Operation): 5% to 95% (non-condensing)

  • Vibration (Operational): 0.5 g, 10 Hz to 150 Hz

  • Vibration (Non-Operational): 1 g, 10 Hz to 150 Hz

Key Features

  • High-Precision Analog Output: Stable 4–20 mA signals across all channels

  • Wide Environmental Tolerance: Operates in extreme temperatures and high humidity

  • Robust Construction: Withstands operational vibration and transport stress

  • Compact Design: DIN-rail mounting minimizes control cabinet footprint

  • Reliable Integration: Fully compatible with Honeywell DCS and PKS systems

Application Scenarios

  • Chemical and petrochemical plants for actuator and valve control

  • Utilities and power generation for analog signal distribution

  • Manufacturing lines requiring precise multi-channel analog output

  • Any distributed control system requiring robust, high-reliability analog signaling

FAQ

Q: How many analog outputs does the CC-TAOX51 support?
A: The CC-TAOX51 supports 16 independent analog output channels.

Q: What type of output signals does it provide?
A: Each channel delivers a 4–20 mA analog current output.

Q: What is the operating temperature range?
A: It operates reliably from -40 °C to +70 °C.

Q: Can it withstand industrial vibration?
A: Yes, it supports 0.5 g operational vibration and 1 g during transport.

Q: How is it mounted in control cabinets?
A: The module is designed for DIN-rail mounting.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more