Skip to content

What are you looking for?


You may also like

Allen-Bradley MicroLogix 1400 | 1766-L32BXBA | Programmable ControllerAllen-Bradley MicroLogix 1400 | 1766-L32BXBA | Programmable ControllerAllen-Bradley MicroLogix 1400 | 1766-L32BXBA | Programmable Controller
Allen-Bradley MicroLogix 1400 | 1766-L32BXBA | Programmable Controller
Allen-Bradley MicroLogix 1400 | 1766-L32BXBA | Programmable Controller
Allen-Bradley MicroLogix 1400 | 1766-L32BXBA | Programmable Controller

Allen-Bradley MicroLogix 1400 | 1766-L32BXBA | Programmable Controller


Only 10 left - Selling fast

PRODUCT SKU : 1766-L32BXBA

PRODUCT TYPE : Programmable Logic Controller

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1766-L32BXBA MicroLogix 1400 controller is engineered for versatile automation tasks, offering a balanced mix of digital and analog I/O, multiple communication options, and reliable performance in industrial environments.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line MicroLogix 1400

  • Part Number 1766-L32BXBA

  • Weight 1.75 lbs (0.79 kg)

  • Total I/O Capacity 32 points

  • Digital Inputs 12 fast 24V DC, 8 standard 24V DC

  • Input Voltage Range 0–24V DC

  • Digital Outputs 6 relay, 3 fast 24V DC, 3 standard 24V DC

  • Relay Output Range 5–125V DC / 5–264V AC

  • Analog Inputs 2 voltage channels (0–10V DC, 1 LSB resolution)

  • Analog Outputs 2 voltage channels

  • Operating Frequency 47–63 Hz

  • Power Supply 24V DC

  • Inrush Current 15 A for 20 ms

  • Communication Ports 1 isolated RS232/RS485 combo, 1 non-isolated RS232, 1 Ethernet

  • Supported Protocols DF1, ASCII, Modbus RTU, DNP3, DH485, Ethernet/IP, Modbus TCP/IP

  • Memory 20 KB

  • Special Features Built-in real-time clock (RTC)

Application Scenarios

  • Machine-level control with mixed signal requirements

  • High-speed input/output operations such as counters and pulse detection

  • Remote monitoring and SCADA integration via Ethernet/IP or Modbus TCP/IP

  • Compact automation systems requiring reliable relay and DC outputs

FAQ

Q: Can expansion modules be added to this controller?  A: Yes, the MicroLogix 1400 series supports expansion I/O modules for extended functionality.

Q: What is the advantage of fast DC inputs and outputs?  A: They are optimized for high-speed applications, ensuring accurate detection of pulses and rapid switching.

Q: Is the Ethernet port suitable for SCADA integration?  A: Yes, it supports Ethernet/IP and Modbus TCP/IP, making it compatible with most SCADA systems.

Comparison with Similar Models

  • 1766-L32AWA: AC-powered variant, suitable for installations without DC supply.

  • 1766-L32BXB: Similar configuration but excludes relay outputs.

  • 1766-L32BXBA: Offers both relay and DC outputs, ideal for hybrid applications.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more