Product Description

The Allen Bradley ControlLogix 1756-L62S is a GuardLogix controller module designed for safety and standard control applications. It offers 4 MB of user memory, 478 KB of I/O memory, and supports up to 128,000 digital I/O points. With dual current draw ratings, low power dissipation, and open-style enclosure, the 1756-L62S provides reliable performance in complex automation systems.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: ControlLogix

  • Catalog Number / Model: 1756-L62S

  • Category: PLCs

  • Module Type: GuardLogix Controller

  • Weight: 1.19 lbs (0.54 kg)

  • User Memory: 4 MB

  • I/O Memory: 478 KB

  • Maximum Digital I/O: 128,000

  • Maximum Analog I/O: 4,000

  • Current Draw (5.1 VDC): 1200 mA

  • Current Draw (24 VDC): 14 mA

  • Power Dissipation: 3.5 W

  • Thermal Dissipation: 11.9 BTU/hr

  • Isolation Voltage: 30 V continuous

  • Enclosure Type: Open-style

Application Scenarios

  • Safety-critical automation systems requiring GuardLogix functionality

  • Large-scale industrial control with high I/O capacity

  • Environments needing reliable memory and communication performance

FAQ

Q: How much user memory does the 1756-L62S provide?  A: 4 MB of user memory.

Q: What is the maximum supported I/O capacity?  A: Up to 128,000 digital I/O and 4,000 analog I/O.

Q: What type of enclosure does the module use?  A: Open-style enclosure.

Comparison with Similar Models

  • 1756-L62S: 4 MB user memory, GuardLogix safety controller.

  • 1756-L61: 2 MB user memory, standard ControlLogix controller.

  • 1756-L63: 8 MB user memory, higher performance ControlLogix controller.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more