Skip to content

What are you looking for?


You may also like

Allen Bradley 2711P-T10C22D8S PanelView Plus 7 Performance Touch TerminalAllen Bradley 2711P-T10C22D8S PanelView Plus 7 Performance Touch TerminalAllen Bradley 2711P-T10C22D8S PanelView Plus 7 Performance Touch Terminal
Allen Bradley 2711P-T10C22D8S PanelView Plus 7 Performance Touch Terminal
Allen Bradley 2711P-T10C22D8S PanelView Plus 7 Performance Touch Terminal
Allen Bradley 2711P-T10C22D8S PanelView Plus 7 Performance Touch Terminal

Allen Bradley 2711P-T10C22D8S PanelView Plus 7 Performance Touch Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T10C22D8S

PRODUCT TYPE : Touch Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711P-T10C22D8S functions as a premier operator interface within the PanelView™ Plus 7 Performance series. This high-definition 10.4-inch terminal streamlines machine-level monitoring and control by providing a vibrant SVGA color display and responsive touch-input capabilities. It integrates seamlessly into complex, data-intensive automation environments through the FactoryTalk® View Machine Edition (ME) software. We offer this unit as 100% brand new and original, ensuring your control system utilizes the most current hardware revisions for optimal processing speed and screen clarity.

Technical Specifications

The 2711P-T10C22D8S provides professional-grade visualization in a rugged industrial package:

Feature Specification
Operator Input Analog Resistive Touch
Display Type Color Active Matrix TFT
Diagonal Size 10.4-in.
Resolution 800 x 600 SVGA (18-bit Graphics)
Viewing Area (W x H) 211 x 158 mm (8.3 x 6.2 in.)
Power Input 24V DC
Communication Ports Dual EtherNet/IP (Supports DLR)
Dimensions (WxHxD) 29.7 x 25.2 x 6.96 cm
Weight 2.28 kg (5.03 lbs)

Engineering Advantages

  • Optimized Network Resiliency: The 2711P-T10C22D8S features dual Ethernet ports that support Device Level Ring (DLR) topologies. This ensures continuous HMI communication even if a single point in the network ring breaks, preventing visual blind spots during production.

  • Superior Visual Clarity: The 18-bit color graphics and SVGA resolution deliver sharp, high-contrast process screens. This detail allows operators to identify alarm conditions and process variables quickly, reducing human error in complex decision-making environments.

  • Robust Hardware Architecture: The "Performance" designation indicates increased processor speed and memory compared to the Standard series. This module handles large-scale FactoryTalk projects with numerous tags and high-resolution trending without experiencing lag.

  • Simplified Field Maintenance: The terminal utilizes a modular design that facilitates easy mounting and component replacement. The 2711P-T10C22D8S fits into standard panel cutouts, utilizing a secure mounting clip system that maintains an IP66/NEMA 4X seal against dust and moisture.

  • Advanced Integration: This terminal natively supports advanced controller tags and complex alarm structures from Logix-based controllers. It synchronizes seamlessly with Studio 5000 projects, significantly reducing the time required for HMI screen development.

FAQs

  • Does the 2711P-T10C22D8S support remote access monitoring?

    Yes. The Performance series supports VNC (Virtual Network Computing) server functionality. This allows plant managers to view and control the HMI screen remotely via a PC, tablet, or smartphone for troubleshooting and status checks.

  • Is this a 100% brand new Allen Bradley unit?

    Absolutely. We guarantee that every 2711P-T10C22D8S we ship is brand new and original in factory-sealed packaging. It arrives with the full manufacturer’s assurance of quality and E-E-A-T industrial compliance.

  • What is the difference between the 'D8S' and 'D9P' suffixes?

    Suffixes typically designate hardware revisions, regional certifications, or branding updates. The "S" designation in the 2711P-T10C22D8S confirms it meets the latest Performance specifications for global markets.

  • What mounting precautions should I follow?

    Always verify the panel cutout dimensions before installation. Ensure the gasket is seated correctly and tighten the mounting clips to the specified torque to maintain the NEMA 4X environmental rating for washdown environments.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more
Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Selecting the correct control platform represents a foundational engineering decision in factory automation. System designers must carefully balance technical parameters against long-term operational requirements when implementing a Programmable Logic Controller (PLC). This article examines the critical evaluation metrics, physical scale classifications, and operational architectures of modern control systems.

Read more